Acquire the Signal
Standard
CAN 2.0
CAN FD
Bit Rate
500 kbps
FD Bit
Rate
4 Mbps
6.
Push
Standard
to select between CAN 2.0
and CAN FD decode/trigger standards.
While CAN FD is backwards compatible
with CAN 2.0 packets, CAN 2.0 should be
selected for best performance with non CAN
FD bus con
fi
gurations.
FD
Standard
ISO
non-ISO
7.
Push
Bit Rate
, and turn
Multipurpose a
to select from the list of prede
fi
ned bit rates.
Alternatively, you can set the bit rate to a speci
fi
c value. To do so, select Custom, and then turn
Multipurpose b
to set the
bit rate from 10 kbps to 1 Mbps.
When Standard is set to CAN FD, this will be the SD bit rate.
8.
If Standard is set to CAN FD, push
FD Bit Rate
, and turn
Multipurpose a
to select from the list of prede
fi
ned bit rates.
Alternatively, you can set the bit rate to a speci
fi
c value. To do so, select Custom, and then turn
Multipurpose b
to set
the bit rate from 500 kbps to 7 Mbps for the MDO3000.
9.
If Standard is set to CAN FD, push
FD Standard
to select between ISO (11898-1:2015) and non-ISO (Bosch:2012)
protocol standards.
76
MDO3000 Series Oscilloscopes User Manual
Содержание MDO3012
Страница 1: ...x MDO3000 Series Mixed Domain Oscilloscopes ZZZ User Manual P077096802 077 0968 02...
Страница 2: ......
Страница 3: ...MDO3000 Series Mixed Domain Oscilloscopes ZZZ User Manual xx www tek com 077 0968 02...
Страница 10: ...Table of Contents iv MDO3000 Series Oscilloscopes User Manual...
Страница 236: ...Appendix D OpenSSL License 214 MDO3000 Series Oscilloscopes User Manual...