2.5 The Building
The smallest fully functional PLC unit of the TC600 series is formed by
the basic module (BM). It is produced in six designs which differ in the num-
ber and type of inputs and outputs.
Type
Order Number
1)
Note
Binary
inputs
Analog
inputs
Transist.
outputs
Relay
outputs
TC601
TXN 061 51
12
-
8
-
TC602
TXN 061 52
20
-
16
-
TC603
TXN 061 53._ _
12
-
4
4
TC604
TXN 061 54._ _
16
-
-
10
TC605
TXN 061 55._ _
12
4
-
8
TC606
TXN 061 56._ _
16
4
4
10
TC607
TXN 061 57._ _
20
-
20
-
1)
In types TC603 to TC607, the after-number (two digits after the dot)
determine the special BM function:
.00 common function of binary inputs (after-number need not be given)
.01 4 interruption binary inputs
.03 measuring by incremental position scanner
.05 counter of type 3 (unidirectional 16 bit counter with pre-selection)
.06 period and phase shift measurement
Optional part of all BM types are interfaces of two serial communications
channels (CH1, CH2) fitted in the standard design, additional data memory
(DataBox), and a third serial communication channel (CH3) or analog out-
puts.
Type
Order number
Note
MR-02
5XK 068 91
Interface RS-232 without galvanic separation
from internal control circuits
MR-04
5XK 068 93
Interface RS-485 without galvanic separation
from internal control circuits
MR-09
TXK 085 03
Interface RS-485 with galvanic separation from
internal control circuits
MR-17
TXK 085 11
Interface RS-422 without galvanic separation
from internal control circuits
IM-70
TXK 080 10.00
DataBox, additional data memory 128 kB
1)
IM-70
TXK 080 10.02
DataBox, additional data memory 512 kB
1)
MR-14
TXK 085 08.02
CH3 with interface RS-485 without galvanic
separation from internal control circuits
2)
MR-15
TXK 085 09.02
CH3 with RS-232 without galvanic separation
from internal control circuits
2)
OT-13
TXK 082 60
4 analog outputs without galvanic separation
from internal control circuits
2)
OT-14
TXK 082 61
8 analog outputs without galvanic separation
from internal control circuits
2)
1)
DataBox is added in the production plant exclusively
2)
Only 1 piggyback MR-xx or 1 piggyback OT-xx may be fitted
Number of binary and analog inputs and binary outputs of the BM can be
extended by connecting one extension module (EM), two half extension mo-
dules (EM/2) or by combination of EM, EM/2.
Order numbers for
BM PLC of the TC600
series
Order numbers of
optional BM
piggybacks