48
12 /13 UP / DOWN command
RUN
UP
DOWN
Output
frequency Fn_25
Note:
To utilize the up and down function (Fn_11) must be set to terminal control.
When using this function set (Fn_03) to the (0xxx) position. The T-verter will accelerate to the
target frequency set at (Fn_25) after the designated terminal is turned on, the drive will remain at
what ever speed it was at when the contact terminal was released.
When the (UP) or (DOWN) terminal is engaged, the T-verter starts accelerating or decelerating.
When the UP or DOWN signal disappears, the T-verter will stay at the current frequency. Once
the operating signal is off, the T-verter will decelerate to a stop or stop immediately (decided by
Fn_44), the operation frequency will be recorded in (Fn_25)
Terminal UP or DOWN control is inactive during the stop mode. The target frequency must be
changed at (Fn_25) through the Keypad.
Fn_61:
Multi-Function Output: Terminals 10 / 11
00: Run Mode
01: At Target Speed
02: Set Frequency (Fn_08) +/- (Fn_09)
03: Frequency Detection > (Fn_08)
04: Frequency Detection < (Fn_08)
05: Over Current Detection
06: Change contact status From (NO) to (NC)