12
Horsepower
Power source Max.
Volts
Amps
0.5/1/2/3
200 – 240V
1/2
380 – 480V
300 20
5/7.5/10 200
–240V
3/5/7.5/10 380
–480V
600 40
15/20 200
–240V
15/20/25/30 380
–480V
600 60
25/30 200
–240V
600
100
Note: Nominal values of input and output signals (TM2) – follow the specifications of class 2
wiring.
2. Fuse
types
To protect the inverter most effectively, use fuses with current-restraint function.
Horsepower
Power source Max.
Rated fuse specifications
2
15A, 600VAC, 100KA, I.R.
3
20A, 600VAC, 100KA, I.R.
5
30A, 600VAC, 100KA, I.R.
7.5/10
60A, 600VAC, 100KA, I.R.
15/20
100A, 600VAC, 100KA, I.R.
25/30
200 – 240V
150A, 600VAC, 100KA, I.R.
1
5A, 600VAC, 100KA, I.R.
2
10A, 600VAC, 100KA, I.R.
3
15A, 600VAC, 100KA, I.R.
5
20A, 600VAC, 100KA, I.R.
7.5/10
40A, 600VAC, 100KA, I.R.
15/20
70A, 600VAC, 100KA, I.R.
25/30
380 – 480V
100A, 600VAC, 100KA, I.R.