3.2 ELECTRICAL INSTALLATION (machines with water condensation)
The electrical system to which the machine is connected must be perfectly executed by a Qualified
electrician in compliance with current regulations. An efficient electrical system with adequate
earthing is of vital importance to ensure trouble-free operation of your machine.
We recommend installing an automatic wall differential switch. See tables below for power and absorption data
depending on the machine and voltage.
The line cable has four wires: the
yellow/green
wire is the
earth
and the other three are the three
phases.
MANTE 1545
V.220
50 HZ
V.220
60 HZ
V.400
50 HZ
Total power
KW.
5
5
5
Maximum absorption
A.
22
22
16
Line cable N. wires and section
4 x 4 mm²
4 x 4 mm²
4 x 2.5 mm²
MANTE 2060
V.220
50 HZ
V.220
60 HZ
V.400
50 HZ
Total power
KW.
7,3
7,3
6
Maximum absorption
A.
43
43
21
Line cable N. wires and section
4 x 6 mm²
4 x 6 mm²
4 x 4 mm²
MANTE 30 100
V.220
50 HZ
V.220
60 HZ
V.400
50 HZ
Total power
KW.
12
12
11
Maximum absorption
A.
55
55
25
Line cable N. wires and section
4 x10 mm²
4 x 10 mm²
4 x 6 mm²
3.5 WATER INSTALLATION AND CONSUMPTION
Connect the fitting with the writing
ENTRATA ACQUA - WATER INLET
to the hose from the water mains; connect the
fitting with the writing
USCITA ACQUA - WATER OUTLET
to the drain hose.
If the machine works with mains water supply (medium temperature
20°C
), make sure that the water coming into the
machine has a
minimum pressure of 1.5 bar.
If the water pressure is above
5 bar,
have the plumber mount a pressure
reducer that reduces it to
4 bar.
The average consumption of
non salty
mains or well
water (when the refrigerator system works) is:
If the machine works with Tower water, this must have a
maximum inlet temperature of
29°C
.
- MANTE 15 45 = 100/190 litres/hour*
- MANTE 20 60 = 150/250 litres/hour*
- MANTE 30 100 = 300/450 litres/hour*
* depending on inlet water temperature
The amount of water that must circulate at a minimum
pressure of
2.5 Bar
must be:
- MANTE 15 45 = 300/600 litres/hour*
- MANTE 20 60 = 450/750 litres/hour*
- MANTE 30 100 = 900/1350 litres/hour*
* depending on inlet water temperature
If the water contains any impurities, it will be absolutely essential to fit a purifying filter to avoid any danger of
build-up of scale and/or damage to the pressure valve and condenser of the refrigerator system.