Gas Connection
General Overview
WARNING:
THE GAS SUPPLY HOSE SHOULD BE
INSPECTED PRIOR TO EACH USE. DO NOT USE A GAS
HOSE THAT HAS ABRASION, CUTS OR EXCESSIVE
WEAR. IF DAMAGE IS PRESENT THE HOSE MUST BE
REPLACED WITH A TEC SPECIFIED HOSE PRIOR TO
USING THE GRILL. A LIST OF REPLACEMENT PARTS
CAN BE FOUND IN APPENDIX C.
WARNING:
WHEN YOUR GRILL IS STORED INDOORS,
REMOVE AND STORE THE LP GAS CYLINDER
OUTDOORS IN A PROTECTED, COOL AND DRY
LOCATION OUT OF REACH OF CHILDREN. THE
CYLINDER SHOULD NOT BE STORED IN A BUILDING,
GARAGE OR ANY OTHER ENCLOSED AREA.
Follow the procedures outlined in this section closely to
ensure safe and proper grill operation. The Sterling G-
Series grill is offered in one of two gas configurations: LP
or Natural gas. Reference Table A.1 below for regulator
specifications. Grills that do not use LP gas with standard
20 lb. LP cylinder must be installed by qualified
personnel. This includes all Natural gas and permanently
installed units. Gas regulators specified by TEC should be
used at all times. Refer to Table A.1 below for gas supply
specifications or see rating plate located inside the grill
drip tray (front left corner).
LP Gas Cylinder Safety
WARNING:
WHEN PURCHASED FOR USE WITH LP
GAS, THE G-SERIES GRILL COMES WITH A
REGULATOR ASSEMBLY THAT USES A TYPE I
CYLINDER CONNECTION DEVICE. THIS DEVICE MUST
BE USED WITH A TYPE I VALVE CYLINDER
CONNECTION.
NOTICE:
AN LP GAS CYLINDER IS NOT PROVIDED
FROM THE FACTORY WITH THIS GRILL. HOWEVER,
ONLY APPROVED 20 LB. LP GAS CYLINDERS
CONSTRUCTED AND MARKED IN ACCORDANCE WITH
THE
SPECIFICATIONS FOR LP GAS CYLINDERS OF THE
U.S. DEPARTMENT OF TRANSPORTATION (D.O.T) OR
NATIONAL STANDARD OF CANADA, CAN/CGA-B339,
CYLINDERS, SPHERES AND TUBES FOR THE
TRANSPORTATION OF DANGEROUS GOODS; AND
COMMISSION, SHOULD BE USED. ALL APPROVED
CYLINDERS MUST BE EQUIPPED WITH AN INTEGRAL
COLLAR DESIGNED TO PROTECT THE CYLINDER
VALVE FROM DAMAGE, AS WELL AS A LISTED
OVERFILL PROTECTION DEVICE. DO NOT USE OR TRY
TO REPAIR A DAMAGED LP GAS CYLINDER AT ANY
TIME. CONTACT YOUR LOCAL LP GAS SUPPLIER FOR
REPLACEMENT. ALSO, YOU SHOULD ALWAYS
OBSERVE THE FOLLOWING PRECAUTIONS:
■
Do not store a spare gas cylinder under or within 15
feet of this grill or any other open flame, heat
producing appliance or heat source.
■
Do not fill your gas cylinder beyond
3
/
4
full.
■
Gas cylinders come with a pressure relief valve. If a
cylinder is subjected to excessive heat, the relief valve
will open and let highly flammable gas vapor and/or
liquid escape. Therefore, do not store gas cylinders
near or under an open flame or source of heat. Store
cylinders only in outside well ventilated areas.
WARNING:
FAILURE TO FOLLOW THE ABOVE
PRECAUTIONS COULD RESULT IN A FIRE CAUSING
DEATH OR SERIOUS INJURY OR PROPERTY DAMAGE.
GAS, REGULATOR
SUPPLY PRESSURE
OPERATING PRESSURE
MAIN BURNER
BURNER INPUT
AND BASE TYPE
(IN. WC (kPa), MAX/MIN)
(IN. WC (kPa))
ORIFICE SIZE (DMS / DIA.)
(BTU/HR. (W)/EA.)
Natural
14.0 (3.4)/5.0 (1.2)
4.0 (1.0)
46 (0.0810")
19,500 (5,715)
model RV-47L (NG)
stationary
LP
14.0 (3.4)/12.0 (3.0)
11.0 (2.7)
55 (0.0520")
19,500 (5,715)
model RV-47L (LP)
stationary
LP
125 psi (861), max
11.0 (2.7)
55 (0.0520")
19,500 (5,715)
model 5001 or 718A
w/hose 20 lbs. cylinder
Table A.1.
Gas Supply Specifications
Содержание Sterling