TEC Sterling Скачать руководство пользователя страница 3

1

Notice to Customer

PRIOR TO INSTALLING AND USING THIS APPLIANCE,
READ THIS MANUAL FULLY AND CAREFULLY. RETAIN
THIS MANUAL FOR FUTURE REFERENCE AND HAVE
AVAILABLE AT ALL TIMES. ENSURE THAT ALL
PERSONS OPERATING THIS EQUIPMENT CAREFULLY
READ AND BECOME FAMILIAR WITH THE
INFORMATION IN THIS MANUAL.

THIS UNIT HAS BEEN CAREFULLY INSPECTED AND
PACKAGED AT THE FACTORY PRIOR TO SHIPMENT.
UPON ARRIVAL, INSPECT THE APPLIANCE
CAREFULLY FOR ANY CONCEALED DAMAGE.
IMMEDIATELY REPORT ANY DAMAGE TO YOUR
AUTHORIZED DEALER.

SHOULD YOU HAVE ANY QUESTIONS REGARDING
OPERATION OR USE OF THIS APPLIANCE, CONTACT
THERMAL ENGINEERING CORPORATION AT
(803) 783-0750 OR 1-800-331-0097.

Notice to Installer

INSTALLATION MUST CONFORM TO LOCAL CODES OR
THE NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54.
IN CANADA, INSTALLATION OF THIS PRODUCT
SHOULD BE IN ACCORDANCE WITH THE CAN/CGA-
B149.1 NATURAL GAS AND PROPANE INSTALLATION
CODE. FOLLOWING  INSTALLATION, LEAVE THIS
OPERATIONS MANUAL WITH THE CONSUMER FOR
FUTURE REFERENCE. THIS APPLIANCE IS NOT
INTENDED FOR USE ON RECREATIONAL VEHICLES
AND/OR BOATS.

FOR YOUR SAFETY

IF YOU SMELL GAS:

1.  SHUT OFF GAS TO THE APPLIANCE.
2.  EXTINGUISH ANY OPEN FLAME.
3. OPEN 

LID.

4.  IF ODOR CONTINUES, IMMEDIATELY CALL YOUR

GAS SUPPLIER OR YOUR FIRE DEPARTMENT.

FOR YOUR SAFETY

1.  DO NOT STORE OR USE GASOLINE OR OTHER

FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE.

2.  AN LP CYLINDER NOT CONNECTED FOR USE

SHALL NOT BE STORED IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.

Warnings

Notices

Warnings to Customer

DO NOT INSTALL OR OPERATE THIS APPLIANCE
WITHOUT HAVING CAREFULLY READ THIS MANUAL.
FOR FUTURE REFERENCE, HAVE THIS MANUAL
AVAILABLE WHILE USING THIS APPLIANCE AND
ALWAYS FOLLOW THE INSTRUCTIONS PROVIDED.

NEVER ATTEMPT TO MAKE CONVERSIONS OR
MODIFICATIONS TO YOUR GRILL WITHOUT FIRST
OBTAINING WRITTEN INSTRUCTIONS FROM THERMAL
ENGINEERING CORPORATION.

DO NOT STORE A SPARE GAS CYLINDER UNDER OR
WITHIN 15 FEET OF THIS GRILL, OR ANY OTHER
OPEN FLAME, HEAT PRODUCING APPLIANCE OR
HEAT SOURCE.

DO NOT ALLOW YOUR LP GAS CYLINDER TO BE
FILLED BEYOND 

3

/

4

FULL.

WARNING:

FAILURE TO FOLLOW THESE

INSTRUCTIONS CAN RESULT IN A FIRE CAUSING
DEATH OR SERIOUS INJURY OR PROPERTY DAMAGE.

NATIONALLY REGISTERED TESTING LABORATORY

U.S. Patent # 6114666
U.S. Patent # 4886044
U.S. Patent # 4321857
Des. 266,050

© Thermal Engineering Corporation, Revised (09/04)

Revised 09/04

Содержание Sterling

Страница 1: ...hermal Engineering Corporation P O Box 868 Columbia South Carolina 29202 0868 2741 The Boulevard Columbia South Carolina 29209 Telephone 803 783 0750 Toll free 800 331 0097 Fax 803 783 0756 Toll free...

Страница 2: ...INSERT PAGE HERE...

Страница 3: ...IF YOU SMELL GAS 1 SHUT OFF GAS TO THE APPLIANCE 2 EXTINGUISH ANY OPEN FLAME 3 OPEN LID 4 IF ODOR CONTINUES IMMEDIATELY CALL YOUR GAS SUPPLIER OR YOUR FIRE DEPARTMENT FOR YOUR SAFETY 1 DO NOT STORE O...

Страница 4: ...ge caused by failure to follow the instructions in your Owner s Manual or alteration of the grill structure or components or from operator abuse negligence or accident DISCLAIMER OF IMPLIED WARRANTIES...

Страница 5: ...e of accessories that afford you a wide range of opportunities for new and interesting uses of your grill Some of them like our rotisserie are options familiar to everyone Others like our deep fryer a...

Страница 6: ...ent masonry or other suitable patio fixture or for mounting onto a mobile cabinet base See Appendix A for complete build in specifications Figure 1 page 5 shows the minimum required clearance of a mob...

Страница 7: ...are on with one hand The base can be locked in place using the Base Brake mechanism WHICH SHOULD BE ENGAGED AT ALL TIMES See BASE BRAKE section on page 11 for more information General Overview You wil...

Страница 8: ...B LP GAS CYLINDERS CONSTRUCTED AND MARKED IN ACCORDANCE WITH THE SPECIFICATIONS FOR LP GAS CYLINDERS OF THE U S DEPARTMENT OF TRANSPORTATION D O T OR NATIONAL STANDARD OF CANADA CAN CGA B339 CYLINDERS...

Страница 9: ...from Cylinder Valve Outlet and Nipple as necessary 5 Inspect the Coupling Nut Nipple and Cylinder Valve for any damage dirt or debris Remove dirt or debris Replace any damaged parts with TEC specifie...

Страница 10: ...ed This Valve must be design certified by CSA International The grill and Shut off Valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressu...

Страница 11: ...using the Handwheel See Figure 2 Page 7 For Natural gas open the gas valve in the main line 4 Depress and rotate the Burner Output Knob to HIGH See Figure 5 5 Slowly rotate Spark Igniter knob clockwis...

Страница 12: ...ip Tray being careful to locate the match between the burners While watching the flame to ensure that the match remains lit turn the Burner Output Knob for the burner to be lit to HIGH 6 Repeat this p...

Страница 13: ...sh this look down under the glass at the burner while turning the adjustment screw Base Brake Your Sterling G Series cabinet comes equipped with a Base Brake mechanism for use while the grill is stati...

Страница 14: ...and smoke greatly enhance the flavor by char broiling the food Smoking Method The G Series grill can be used very effectively as a smoker Use dry wood pellets or wet woodchips small chips not chunks...

Страница 15: ...6 min Pork Chops Medium 6 min per side Spare Ribs High fire 5 min 20 min per side Low to finish Turn often Lamb Chops High fire 5 min 15 min per side Medium to finish Fish 1 lb Medium Low 6 8 min per...

Страница 16: ...es should be avoided because they may leave small hard to remove deposits on the glass Protection of Burners The burners of your grill are designed to provide a long life of satisfactory performance H...

Страница 17: ...ny charred residue and wipe glass with a damp paper towel as described under Care of Radiant Glass Emitter With a cool surface apply a few dabs the size of a dime of an approved cleaner and work the c...

Страница 18: ...ning Vertical Depth of Opening Vertical Height of Counter Horizontal Width of Opening G3000 suggested height dimension 16 16 12 1 4 1 2 unobstructed ventilation area under front of cooking unit D B A...

Страница 19: ...e Burner Ignition Procedures on pages 9 and 10 After the burner ignites operate the grill for 3 to 5 minutes on HIGH with the hood OPEN 3 Turn the Burner Output Knob to LOW Position the spit rod in th...

Страница 20: ...HEAT AND EXTINGUISH WITH A CLASS A B C D FIRE EXTINGUISHER OR COVER FRYER WITH STEAMER LID UNTIL COOLED DO NOT PUT WATER ON HOT OR FLAMING OIL 1 Remove the Cooking Grid over the burner that will be u...

Страница 21: ...ter or other non flammable liquid wine etc Repeat this throughout the cooking process so that the liquid level is maintained 4 Place the Steamer Screen in the bottom of the Fryer Cover the Deep Fryer...

Страница 22: ...CE ALWAYS LEAVE AT LEAST 25 OF THE SURFACE OPEN FOR VENTILATION Griddle Use 1 Remove the Cooking Grid of the desired burner 2 Place the Griddle over the burner 3 Follow the Burner Ignition Procedures...

Страница 23: ...G COOKING SURFACE ALWAYS LEAVE AT LEAST 25 OF THE SURFACE OPEN FOR VENTILATION Wok Use 1 Remove the Cooking Grid of the desired burner 2 Place the Wok support over the burner 3 Place the Wok in the Wo...

Страница 24: ...660 for Sterling G4000 Drip Tray RFM1677 for Sterling G4000 Warming Rack RFM1659 for Sterling G4000 Heat Shield REG102QD Regulator w hose LP gas REGLP Regulator LP gas build in applications REGNT Regu...

Страница 25: ...See Fig 8 Pg 10 f Adjust or replace regulator as necessary g Contact TEC Authorized Dealer Replace ceramic burner head Burner output at LOW setting is too hot or too cool a Reduce or increase low hea...

Страница 26: ...Notes...

Отзывы: