Teac DS Series Скачать руководство пользователя страница 32

 

Page 24 

1.

 Go to the <RECORD> menu. 

 

 

 

2.

 Move the cursor to [SAMPLE] by pressing the down key. 

 

 

 

3.

  Press  the  ENTER  key  to  go  to  <SAMPLE>.    The  selectable  sampling  frequencies  are 

displayed.   

 

 

 

4.

 Move the cursor to a desired sampling frequency you want to set. 

 

 

 

5.

 Press the ENTER key to display the confirmation for the current selection. 

 

 

 

 

 

 

Содержание DS Series

Страница 1: ...ten materials In no event shall TEAC be liable for any damages whatsoever including without limitation damages for loss of business profits business interruption loss of business information or other...

Страница 2: ...ference at his own expense Caution Changes or modifications to this equipment not expressly approved by TEAC CORPORATION for compliance could void the user s authority to operate this equipment For th...

Страница 3: ...6 1 2 Auto Range Page 17 6 1 3 Input Mode Setting Page 19 6 1 4 Zero Shift Page 20 6 1 5 Manual Calibration Page 21 6 2 Sampling Frequency Setting Page 23 6 3 Number of Recording Channels Setting Pag...

Страница 4: ...to Playback Page 62 10 3 Select Playback Sampling Frequency Page 63 10 3 1 AUTO Mode Page 65 10 3 2 FIXED Mode Page 66 10 4 Output Range Setting Page 67 11 CONNECT TO PC Page 69 12 NETWORK MENU Page...

Страница 5: ...have been adhered to 10 Power Sources This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supply to your home con...

Страница 6: ...lified technician to restore the product to its normal operation e If the product has been dropped or damaged in any way f If the product exhibits a distinct change in performance 18 Replacement Parts...

Страница 7: ...Page v Note...

Страница 8: ...Page vi Note...

Страница 9: ...maximum rate of 16M words sec Playback from the internal hard disk drive at the maximum rate of 8M words sec and the maximum playback sampling frequency of 500 kHz Types of the input amplifier selecta...

Страница 10: ...o enter the record standby state 9 PAUSE Press to pause recording to enter the record standby state 10 EVENT Press to write an event mark 11 Speaker Speaker 12 Up Down Left Right Keys Press to move th...

Страница 11: ...ion signal input for synchronization recording HIROSE DX10G1M 26SE 5 SYNC OUT Connector for synchronization signal output for synchronization recording HIROSE DX10GM 20SE 6 REMOTE Connector for an opt...

Страница 12: ...0S Connector of Signal Input Cable HIROSE HDDB 50P soldering type JAE DD 50PF N soldering type or equivalent CAUTION Do not connect any signal at Pin 17 Installation of accessory clamp filter Install...

Страница 13: ...nter the necessary settings by using the main and sub menus to be displayed on the LCD How to operate the menus is explained in Section 4 3 Set the record conditions such as the sampling rate etc How...

Страница 14: ...Page 6 Note...

Страница 15: ...tect recording data During a power cut or power interruption the unit closes a file to protect important data from unexpected power cut and interruption The built in battery charge takes approximately...

Страница 16: ...flashing LED on the front panel 6 When the system boots up the next READY is displayed Amount of free space of HDD displayed in Free is different based on the system recording conditions Turning Powe...

Страница 17: ...alue and gain of each channel and then writes the new value into ROM of each amplifier card Read 6 1 5 Manual Calibration on how to carry out the calibration Periodical Manual Calibration Periodical m...

Страница 18: ...ress the main power switch upper part O display side on the rear panel to turn off the main power source POWER LED turns off About Main Power Switch POWER LED keeps turning on red for approximately 4...

Страница 19: ...displayed At the recording unit At the recording and playback unit 4 Use the up and down key to move the cursor The position at which the cursor is located is an effective selection Select the item th...

Страница 20: ...DEL LAST DATA IRIG B Set to use Channel 1 for voice memo Set the output from the internal speaker Exchange the internal HDD Format the internal HDD Delete the last recorded file Set to display the ti...

Страница 21: ...the system is in ready state READY display 2 Press the right key for 3 seconds is displayed and the key operations are locked 3 To release panel lock state press the right key again for 3 seconds is...

Страница 22: ...Page 14 Note...

Страница 23: ...umber of recording channels by using the LCD and keys of the DS unit To enter the RECORD menu 1 Confirm that the system is in ready state READY display If the system is not in ready state press the ST...

Страница 24: ...cursor is in RANGE 2 The RANGE menu is displayed 3 Move the cursor to the channel to set its input range by pressing the up and down keys You can set all effective channels with the same input range a...

Страница 25: ...changing the percentage in display by using the up and down keys 70 If the signal exceeds 70 for measurement shift to the upper input range 80 If the signal exceeds 80 for measurement shift to the up...

Страница 26: ...the up and down keys to locate the channels to display Press the ENTER key after confirming the selections INPUT AMP is displayed To cancel the auto range measurement Press the ENTER key to return to...

Страница 27: ...input range at ALL Press the left and right keys to select the desired input mode DC DC coupling mode IEPE Turn on the power supply to the sensor connected to the channel Voltage output type accelero...

Страница 28: ...the output signal An example is connecting to an oscilloscope You can set all effective channels with the same zero shift value at ALL The system outputs the signal of Channel 1 and displays the zero...

Страница 29: ...ibration 1 Move the cursor to CALIBRATION by pressing the down keys at the INPUT AMP menu 2 Press the ENTER key to go to CALIBRATION If you want to suspend the manual calibration confirm the cursor is...

Страница 30: ...Page 22 6 Press the ENTER key to return to INPUT AMP...

Страница 31: ...fixed external sampling frequency Effective Sampling Frequency vs Recording Channels Fields indicating OK are effective for setting Sampling Frequency Channel Selections kHz 2ch 4ch 8ch 16ch 32ch 64c...

Страница 32: ...LE by pressing the down key 3 Press the ENTER key to go to SAMPLE The selectable sampling frequencies are displayed 4 Move the cursor to a desired sampling frequency you want to set 5 Press the ENTER...

Страница 33: ...channels at the external sampling mode upon the conditions within the applicable sampling frequencies and at available number of channels 1 Go to the RECORD menu 2 Move the cursor to CHANNEL by press...

Страница 34: ...ot connect to the network drive if its remain capacity is 4GB or less You need an extended capacity of 5 GB or more to your expected recording amount When you select LAN or Both to record to the netwo...

Страница 35: ...Manual 2006 12 Page 27 6 Press the ENTER key to decide the selection The RECORD menu is displayed If you do not want to decide the selection press the STOP key The selection is not effective Then retu...

Страница 36: ...using the internal HDD as a ring format In this mode press REC to start recording refer 7 2 Start and Stop Recording The synchronization recording mode does not support the endless recording The endl...

Страница 37: ...er of the channels This mode is effecting only when the recording to the internal hard disk is selected LEVEL Level trigger mode Set the monitor channel for the level trigger the up or down cross and...

Страница 38: ...ting process the power back up system for data saving is not available for this moment Level Trigger Mode Setting Condition of Level Trigger Activation Recording by the level trigger does not start wh...

Страница 39: ...o LEVEL SETUP at TRIGGER SETUP 6 Press the ENTER key to go to LEVEL SETUP 7 Move the cursor to each setup condition with the left and right keys There are three setup conditions for the level trigger...

Страница 40: ...ide the current selections when the confirmation is displayed About Level Trigger The LED of the START key flashes fast at the REC standby sate You can use a combination of the level trigger and the p...

Страница 41: ...le is for the recording only unit 3 Move the cursor to SYSTEM by pressing the down key 5 Press the ENTER key to go to the SYSTEM menu 6 7 1 Voice Memo Channel Setting You can use Channel 1 either for...

Страница 42: ...Channel 1 records the voice memo not data 5 Press the ENTER key to decide the selection The SYSTEM menu is displayed If you do not want to decide the selection press the STOP key The selection is not...

Страница 43: ...ith the up and down keys OFF Turn off the speaker output MONITOR Output the signal of the monitor channel selected while recording PLAYBACK MEMO Output the voice memo at the playback state when the vo...

Страница 44: ...STEM menu by pressing the down keys 2 Press the ENTER key to go to IRIG B 3 To select the IRIG B recording mode connect the IRIG B time code signal to Channel 2 and then press the ENTER key by confirm...

Страница 45: ...e it the last part of file name due to the limitation of its display size The maximum size which can be specified is 78 bytes 78 characters 1 Confirm that the system is in ready state READY display If...

Страница 46: ...al hard disk drive 3 Press the START key REC is displayed and the system goes into the recording state The LED on the START key lights green flashes to indicate that the system is in recording Elapsed...

Страница 47: ...eady state READY display 8 Each pressing of the PAUSE key or the STOP key creates a data file and an associated header file 9 When the recording starts Press the START key at RECSTANDBY display or pre...

Страница 48: ...urning on the voice memo recording flashes orange on the level display LED of Channel 1 at Stop state READY display to indicate Channel 1 is assigned for the voice memo recording 7 4 Monitor Output wh...

Страница 49: ...ase all data files recorded on the hard disk drive 1 Confirm that the system is in ready state READY display If the system is not in ready state press the STOP key a few times depending on the hierarc...

Страница 50: ...timate time for format above is based on 145GB HDD capacity About Fomat While the format operation the DS unit generates the repeated beep sounds At the NORMAL or PURGE option is selected the progress...

Страница 51: ...the system is not in ready state press the STOP key a few times depending on the hierarchy of the current menu to move to ready state 2 Press the ENTER key to display the main menu MENU Below example...

Страница 52: ...ete the last recorded data file 8 Press the ENTER key to delete the last recorded data file 9 Press the Enter key to return to the SYSTEM menu CAUTION About DELETE LAST FILE Repeating 1 to 9 deletes t...

Страница 53: ...fer to a collection of data resulting from one sampling A data file is a collection of scan repetitions The DS series records the data with 2 GB separated multiple files in case the data exceeds 2 GB...

Страница 54: ...er File Format A sample of a header file made in DS series is shown as follows DATASET THISIS 1 VERSION 1 SERIES CH1_MyCh01 CH2_MyCh02 CH3_MyCh03 CH4_MyCh04 DATE 03 10 2003 TIME 18 45 24 RATE 2 500000...

Страница 55: ...arts by the signal level or an external TTL DS_STOP_CONDX Indicate the recording stop condition SOFT Recording stops with the front panel control or the browser by user LEVEL TTL Recording stops by th...

Страница 56: ...size of the master unit that NUM_SAMPS keyword value of the header file is smaller Operation of Slave Unit If you set the lower sampling frequency the activities of the level display LEDs of the slave...

Страница 57: ...the slave unit 3 When the recording synchronization is ready the LCDs of the master and slave units are displayed as follows Master Unit Slave Unit POWER LED of the slave unit lights orange You can c...

Страница 58: ...pending on the hierarchy of the current menu to move to ready state 2 Press the ENTER key to display the main menu MENU Below example is for the recording only unit 3 Move the cursor to SYSTEM by pres...

Страница 59: ...ard disk drive when the unmouting process approximately 50 seconds is completed 10 Withdraw the internal hard disk tray of the front panel The system displays the following 11 Loosen two fixed screws...

Страница 60: ...xchanging the hard disk drive The system displays the following 14 Then the system locks the exchanged hard disk drive with the mounting process by displaying the following 15 The system goes to the r...

Страница 61: ...firm that the system is in ready state READY display If the system is not in ready state press the STOP key a few times depending on the hierarchy of the current menu to move to ready state 2 Press th...

Страница 62: ...to use for the place to save the settings by pressing the up and down keys Press the ENTER key to display the confirmation 5 Press the ENTER key to decide the selection The PARAMETER menu is displaye...

Страница 63: ...to load the settings is displayed 3 Move the cursor to the name you want to use for the place to load the settings by pressing the up and down keys Press the ENTER key to display the confirmation 4 P...

Страница 64: ...e the initialization If you do not initialize the system settings move the cursor to No 4 Press the ENTER key to start initialization of the system settings by displaying the following 5 The system au...

Страница 65: ...m is in ready state READY display If the system is not in ready state press the STOP key a few times depending on the hierarchy of the current menu to move to ready state 2 Press the ENTER key to disp...

Страница 66: ...rast 1 Display the MISC menu 2 Press the ENTER key by confirming that the cursor is in CONTRAST 3 Adjust the contrast with the up and down keys 4 Press the ENTER key when completing the adjustment The...

Страница 67: ...tem information such as the firmware version etc 1 Display the MISC menu 2 Move the cursor to SYS INFO by pressing the down key 3 Press the ENTER key to view the system information 4 Press the ENTER k...

Страница 68: ...ation on the recording synchronization status 1 Display the MISC menu 2 Move the cursor to SYNC INFO by pressing the down keys 3 Press the ENTER key to view the system recording synchronization status...

Страница 69: ...the current menu to move to ready state 2 Press the START key to playback the last recorded file at the right of PLAY flashes while playback 5 Press the PAUSE key to suspend the playback press the st...

Страница 70: ...ress the ENTER key to display the main menu MENU 3 Press the ENTER key to go to PLAYBACK by confirming that the cursor is in PLAYBACK 4 Press the ENTER key to go to PLAY FILE SELECT by confirming that...

Страница 71: ...OK OK OK OK 250 OK OK OK OK OK 125k 204 8 OK OK OK OK 102 4k 200 OK OK OK OK 100k 192 OK OK OK OK 96k 128 OK OK OK OK OK 125 OK OK OK OK OK 102 4 OK OK OK OK 100 OK OK OK OK 96 OK OK OK OK 64 OK OK OK...

Страница 72: ...he main menu MENU 3 Press the ENTER key to go to PLAYBACK by confirming that the cursor is in PLAYBACK 4 Move the cursor to SAMPLE MODE by pressing the down key 5 Press the ENTER key to go to PLAY SAM...

Страница 73: ...e ENTER key to go to the confirmation of the selection 3 Press the ENTER key to decide the selection The PLAYBACK menu is displayed Press the STOP key to cancel the selections and return to the PLAYBA...

Страница 74: ...NTER key to decide the selection The PLAYBACK menu is displayed Press the STOP key to cancel the selections and return to the PLAYBACK menu 4 Select the playback sampling frequency Move the cursor to...

Страница 75: ...firming that the cursor is in PLAYBACK 4 Move the cursor to RANGE by pressing the down keys 5 Press the ENTER key to go to PLAY RANGE 6 Move the cursor to the channel to set its input range by pressin...

Страница 76: ...Page 68 Note...

Страница 77: ...10BASE T 100BASE TX for setting the record conditions Browser IE 6 0 Refer 12 NETWORK MENU for connecting between the PC and the DS unit Refer 13 CONTROL BY USING BROWSER for the explanations of the b...

Страница 78: ...Page 70 Note...

Страница 79: ...se a communications path that does not pass through a router However in a situation such as when the DS unit is in a remote location and communications are constrained by low speed paths use the DS un...

Страница 80: ...tate press the STOP key a few times depending on the hierarchy of the current menu to move to ready state 2 Press the ENTER key to display the main menu MENU Below example is for the recording only un...

Страница 81: ...he ENTER key by confirming that the cursor is in CHANGE PARAM The CHANGE PARAM menu is displayed 3 Press the ENTER key by confirming that the cursor is in DHCP 4 Move the cursor by using the up and do...

Страница 82: ...IP address Press the left and right keys to move the entry positions and press the up and down keys to change the number of the address in each position 4 Press the ENTER key to enter the setting The...

Страница 83: ...d to the DS unit Set Host Name You can assign the host name to the DS unit by using the browser 1 Display the CHANGE PARAM menu 2 Move the cursor to HOST NAME by pressing the down keys 3 Press the ENT...

Страница 84: ...3 Press the ENTER key to decide the network parameters entered at the CHANGE PARAM menu The following is displayed 4 Press the ENTER key to return to the NETWORK menu Caution After Changing Network P...

Страница 85: ...the network drive see 6 4 Recording Target Device Setting Set Shared Network Drive You can set the network drive by using the browser Specify it from the browser at HOST IP ADDRESS Share Folder Name...

Страница 86: ...Page 78 Note...

Страница 87: ...me to appear The same holds true as it refreshes monitoring data in following cycle The data buffer size of the DS unit is optimized for the higher sampling frequency and the higher channel count so i...

Страница 88: ...display scale and the line color The channel marked at Plot is displayed At the General tab you can set the trigger point on the view data Click Start to open the data view windows by following the se...

Страница 89: ...time and to shut down the system Network Network is used for setting the network parameters At the Net Config tab you can set the network parameters of the system At the Net Drive tab you can specify...

Страница 90: ...k R Record is used for setting the recording target device the sampling frequency and numbers of the recording channels etc R Mode is used for setting the record mode R Level Trig is used for setting...

Страница 91: ...DS Series Instruction Manual 2006 12 Page 83 There are lower hierarchy menus to set the amplifier parameters at the R P Amp tab Click the button to go to the lower hierarchy menu...

Страница 92: ...target data A subfolder named by the data and time YYMMDDhhmmss of the data transfer start is automatically created the transferred data are saved into this subfolder Data transfer is possible for the...

Страница 93: ...When REC STANDBY When REC PLAYBACK display example It displays in red when recording and in green when playing back The Counter window s show hide status can be selected simultaneously with the Prope...

Страница 94: ...DS Press Yes to proceed with the Active X installation The Active X name for the data file deletion is dstool distributed by Teac Instruments Corp About Internet Explorer security In order to use the...

Страница 95: ...X View specification the maximum file size is 2GB Contact us for more detail If the same file name exists in the DS the file cannot be transferred When the file deletion and transfer is performed a fr...

Страница 96: ...target file list box DS side data file name retrieval button PC side data file browse button 4 Press the Retrieve button and the data files in DS are shown in the list Put a check mark on the files t...

Страница 97: ...elect the file to be transferred then press the Transder Data to DS button Press the OK button in the confirmation dialog and the data transfer to DS starts The transfer progress is shown during the t...

Страница 98: ...Page 90 Note...

Страница 99: ...ser applet window C for traffic estimation 3 Failed to Read Cookie Cookie usage is disabled or reached the cookie limit is displayed when trying to display the waveform by using the browser The DS sys...

Страница 100: ...Page 92 Note...

Страница 101: ...62 5 kHz 31 25 kHz 400 kHz 200 kHz 100 kHz 50 kHz 25kHz 40 kHz 20 kHz 256 kHz 128 kHz 64 kHz 32 kHz 512 kHz 409 6 kHz 204 8 kHz 102 4 kHz 51 2 kHz 25 6 kHz 40 96 kHz 20 48 kHz 384 kHz 192 kHz 96 kHz...

Страница 102: ...Page 94 Note...

Страница 103: ...DS Series Instruction Manual 2006 12 Page 95 Note...

Страница 104: ...Copyright 2004 2006 TEAC Corporation All rights reserved TEAC CORPORATION 3 7 3 Naka Cho Musasino Shi Tokyo 180 8550 Japan E mail tic_cs teac co jp Phone 81 422 52 5074 Fax 81 422 52 1990...