45
Model C606
Important: To the Operator
GLYCOL THERMISTOR BAD - Place the power
switch in the OFF position. Call your Taylor
authorized service technician.
PRODUCT DOOR OFF - Place the power switch in
the OFF position. Check for proper installation of the
dispensing door and that the hand screws are tight.
COMP ON TOO LONG - Compressor ran more than
11 consecutive minutes without the product reaching
set point temperature. Clean the condenser filter,
replace the scraper blades and reprime the unit
using fresh mix. If the fault appears again, call your
Taylor authorized service technician.
The
LOCKOUT HISTORY
screen displays a history
of the last 100 soft locks, hard locks, brush clean
dates, or aborted heat cycles. Page numbers are
indicated in the upper right hand corner. Page 1
always contains the most recent failure.
(See Figure 74.)
LOCKOUT HISTORY
2
00/00/00
00:00
Reason
> Exit
Figure 74
The second line of the screen displays the date and
time a failure occurs. The third line indicates the
reason for a failure, or will indicate if a successful
brush cleaning has occurred. Some failures occur
with multiple reasons. When this occurs, a page will
be generated for each reason.
Select the AUTO symbol
or OPTIONAL FLAVOR
symbol
to advance forward or backward to view
each screen.
Listed below are the variable messages that may
appear.
Faults Occurring Entering a Heat Treatment
Cycle
POWER SWITCH OFF -
The power switch is OFF.
AUTO OR STBY OFF -
The control was not in
AUTO or STANDBY.
MIX OUT FAILURE -
A mix out condition was
present.
NO HEAT CYCLE TRIED -
The Auto Heat Time
was set to attempt a heat cycle more than 24 hours
after the last successful heat cycle.
Faults Occurring While in the Heat Mode
HEAT MODE FAILURE -
The 90 minute maximum
allowable heat mode time was exceeded.
COOL MODE FAILURE -
The 120 minute maximum
allowable cool mode time was exceeded.
TOTAL TIME FAILURE -
The 4 hour maximum
allowable total heat treatment time was exceeded.
BRUSH CLEAN TIMEOUT -
The total days in
operation exceeded the brush clean cycle setting.
POWER SWITCH OFF -
The power switch was
turned OFF during the heat cycle.
POWER FAIL IN H/C -
A power failure occurred
during the heat treatment cycle.
(L/R) MIX LOW FAILURE -
The mix level in the
(left/right) Hopper is too low for a successful heat
cycle.
(L/R) BEATER OVLD H/C -
The overload tripped for
the (left/right) side beater motor.
(L/R) BRL THERM FAIL -
The thermistor sensor for
the (left/right) side barrel failed.
(L/R) HOPPER THERM FAIL -
The thermistor
sensor for the (left/right) side hopper failed.
(L/R) HPCO H/C -
The (left/right) side high pressure
switch opened during the heat treatment cycle.
Содержание C606
Страница 6: ...Table of Contents Model C606 Notes ...
Страница 16: ...10 Model C606 Operator Parts Identification 140624 Front View Figure 2 ...
Страница 26: ...20 Model C606 Operator Parts Identification 140624 Accessories Figure 11 ...
Страница 30: ...24 Model C606 Operator Parts Identification Beater Door Assembly Shake Side Figure 14 ...