Step 3
Pour the sanitizing solution over all parts in the
bottom of the mix hopper and allow it to flow into the
freezing cylinder.
Note: You have just sanitized the mix hopper
and parts; therefore, be sure your hands are
clean and sanitized before going on in these
instructions.
Step 4
Prepare two more pails of an approved 100 PPM
sanitizing solution (examples: Kay-5® or
Stera-Sheen®)
.
USE WARM WATER AND
FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 5
Install the air/mix pump assembly at the rear of the
mix hopper. To position the pump on the drive hub,
align the drive slot in the piston with the drive crank
of the drive shaft. Secure the pump in place by
slipping the pump clip over the collar of the pump,
making sure the clip fits into the grooves in the
collar. (See Figure 150.)
Figure 150
Step 6
CAUTION!
Install the pump end of the mix feed tube and
secure with the cotter pin.
Failure to follow this
instruction could result in sanitizer spraying on the
operator.
Step 7
Using the white hopper brush, clean the mix level
sensing probes, the mix hopper, mix inlet hole, the
outside of the agitator drive shaft housing, the
agitator, the air/mix pump, pump clip, mix feed tube
and cotter pin.
Step 8
Pour the two pails of sanitizing solution into the mix
hopper. The sanitizing solution should be within 1”
(25 mm) of the top of the hopper.
Step 9
Using the white hopper brush, scrub the exposed
sides of the hopper. Wait at least five minutes before
proceeding with these instructions.
Step 10
Place the power switch in the ON position.
Step 11
Touch the WASH symbol
. This will cause the
sanitizing solution in the freezing cylinder to come in
contact with all areas of the freezing cylinder.
(See Figure 151.)
Figure 151
Step 12
With a pail beneath the door spout, open and close
the draw valve six times.
Step 13
Touch the PUMP symbol
to sanitize the inside of
the air/mix pump and the mix feed tube.
Step 14
Open the draw valve and draw off all the remaining
sanitizing solution.
IMPORTANT! The unit must NOT be placed in
AUTO until all sanitizing solution has been
removed from the freezing cylinder and proper
priming procedures have been completed.
Содержание C606
Страница 6: ...Table of Contents Model C606 Notes ...
Страница 16: ...10 Model C606 Operator Parts Identification 140624 Front View Figure 2 ...
Страница 26: ...20 Model C606 Operator Parts Identification 140624 Accessories Figure 11 ...
Страница 30: ...24 Model C606 Operator Parts Identification Beater Door Assembly Shake Side Figure 14 ...