44
Model C606
Important: To the Operator
120515
Change the number of days between brush clean
intervals by selecting the AUTO symbol
to
decrease the days or the OPTIONAL FLAVOR
symbol
to increase the number of days. Select
the CALIBRATION symbol
to save the setting
and exit back to the Menu. The number of days
displayed on the brush clean counter will change to
the new setting. (See Figure 71.)
BRUSH CLEAN CYCLE
TIME
14
DAYS
Figure 71
Always comply with local guidelines on the number
of days allowed between brush clean cycles.
The
MIX LEVEL AUDIBLE
option, when enabled,
will alert the operator with an audible tone when
there is mix low or mix out condition. The following
screen is displayed upon selecting this option.
(See Figure 72.)
MIX LEVEL AUDIBLE
ENABLED
>
Enable
Disable
Figure 72
Disable the audible tone feature by selecting the
AUTO symbol
to move the arrow to DISABLE.
Select the CALIBRATION symbol
to save the
new setting and return to the Menu. The control
panel icons for Mix Low and Mix Out will light as the
mix level drops in the hopper but the audible tone
will be disabled.
The
FAULT DESCRIPTION
display will indicate if
there is a fault with the freezer and the side of
freezer where the fault occurred. When no faults are
detected the following screen will be displayed.
(See Figure 73.)
FAULT DESCRIPTION
L: NO FAULT FOUND
R: NO FAULT FOUND
Figure 73
Select the CALIBRATION symbol
to display the
next fault found or return to the Menu if no other
faults exist. Selecting the CALIBRATION symbol
any time faults are displayed will clear the faults if
corrected, upon returning to the Menu screen.
Listed below are the variable messages which will
appear, along with an explanation for the corrective
action.
NO FAULT FOUND - There was no fault found in
the freezer. Nothing will appear on the screen after
this variable message appears.
BEATER OVERLOAD - Press the beater reset
button firmly for the side of the freezer with the fault.
(See page 32.)
HPCO COMPRESSOR - Place the power switch in
the OFF position. Wait 5 minutes for the machine to
cool. Place the power switch in the ON position and
restart each side in AUTO.
HOPPER THERMISTOR BAD - Place the power
switch in the OFF position. Call your Taylor
authorized service technician.
HOPPER OVER TEMP - Place the power switch in
the ON position and verify that the AUTO or
STANDBY symbol is illuminated.
BARREL OVER TEMP - Place the power switch in
the ON position and verify that the AUTO or
STANDBY symbol is illuminated.
BARREL THERMISTOR BAD - Place the power
switch in the OFF position. Call your Taylor
authorized service technician.
Содержание C606
Страница 6: ...Table of Contents Model C606 Notes ...
Страница 16: ...10 Model C606 Operator Parts Identification 140624 Front View Figure 2 ...
Страница 26: ...20 Model C606 Operator Parts Identification 140624 Accessories Figure 11 ...
Страница 30: ...24 Model C606 Operator Parts Identification Beater Door Assembly Shake Side Figure 14 ...