167

Code

 

of

 

message

 

Type

 

of

 

message

 

Cause

 

of

  

error

 

message

 

Removing

 

 

error

 

message

  

E52

 

NFAT

 

Too

 

much

 

air

 

in

 

the

 

petrol

 

fuel

 

or

 

insufficient

 

LPG

 

pressure

 

difference

 

Petrol:

 

Maximum

 

number

 

of

 

air

 

separation

 

attempts

 

exceeded

 

LPG:

 

A

 

pressure

 

difference

 

of

 

less

 

than

 

1

 

bar

 

was

 

detected

 

more

 

than

 

3

 

times

 

during

 

one

 

delivery.

 

E52

1

 

Main

 

pump

 

aeration

 

or

 

low

 

LPG

 

pressure

 

difference

 

E52

2

 

Auxiliary

 

pump

 

aeration

 

Petrol:

 

Check

 

the

 

intake

 

manifold

 

for

 

leaks.

 

LPG:

 

Check

 

the

 

pressure

 

in

 

the

 

supply

 

line

 

and

 

the

 

pressure

 

in

 

the

 

return

 

line

 

of

 

the

 

gas

 

phase

 

discharge

 

and

 

the

 

permeability

 

of

 

the

 

line.

 

Check

 

the

 

setting

 

of

 

the

 

TRAFAG

 

differential

 

pressure

 

switch

 

or

 

on

 

connected

 

pressure

 

sensors.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E53

 

NFAT

 

The

 

dispenser

 

door

 

(cover)

 

was

 

opened

 

The

 

cover

 

sensor

 

has

 

been

 

activated.

 

Close

 

all

 

dispenser

 

doors

 

and

 

covers

 

and

 

clear

 

errors

 

by

 

entering

 

manager

 

or

 

service

 

level

 

setup

 

mode

 

by

 

the

 

remote

 

controller.

 

E54

 

ALERT

 

Vapour

 

recovery

 

system

 

fault

 ‐ 

warning

 

The

 

vapour/fuel

 

ratio

 

is

 

out

 

of

 

range.

 

A

 

deactivation

 

timer

 

has

 

been

 

started

 

(48

 

or

 

72

 

hours)

 

after

 

which

 

fillings

 

points

 

with

 

vapour

 

recovery

 

will

 

be

 

blocked.

 

Eliminate

 

a

 

fault

 

on

 

the

 

vapour

 

recovery

 

system.

  

Call

 

an

 

authorized

 

service

 

centre.

 

E55

 

FATAL

 

 

Vapour

 

recovery

 

system

 

fault

 

 

filling

 

is

 

blocked.

 

Deactivation

 

timer

 

expired.

 

Dispenser

 

is

 

blocked.

 

 

Eliminate

 

a

 

fault

 

on

 

the

 

vapour

 

recovery

 

system.

  

Unlock

 

the

 

vapour

 

recovery

 

system.

 

Call

 

an

 

authorized

 

service

 

centre.

 

E56

 

NFAT

 

Vapour

 

recovery

 

system

 

fault

  

PDEX5:

 

VFS

 

flow

 

meter

 

fault

 

PDEX:

 

Vapour

 

recovery

 

system

 

fault.

 

Troubleshoot

 

the

 

vapour

 

recovery

 

system.

 

PDEX:

 

The

 

VAPORIX

 

system

 

must

 

be

 

unlocked

 

using

 

the

 

service

 

adapter.

 

PDEX5:

 

Check

 

the

 

VFS

 

flow

 

meter

 

and

 

verify

 

that

 

the

 

vacuum

 

pump

 

is

 

working.

 

Call

 

an

 

authorized

 

service

 

centre.

 

E60

 

NFAT

 

CNG:

 

Leakage

 

of

 

the

 

pressure

 

system

 

Check

 

the

 

pressure

 

system

 

for

 

leaks.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E61

 

NFAT

 

CNG:

 

Insufficient

 

pressure

 

rise

 

during

 

leak

 

test

 

Check

 

the

 

pressure

 

system

 

for

 

leaks.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E64

 

NFAT

 

CNG:

 

Insufficient

 

pressure

 

rise

 

during

 

temperature

 

compensation

 

test

 

filling.

 

Check

 

the

 

pressure

 

system

 

for

 

leaks.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E66

 

NFAT

 

CNG:

 

Disconnected

 

or

 

defective

 

pressure

 

sensor

 

Check

 

the

 

connection

 

of

 

the

 

pressure

 

sensor.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre

 

E67

 

FATAL

 

CNG:

 

Dispensing

 

hose

 

break

 

Hose

 

breakaway

 

sensor

 

is

 

active

 

It

 

is

 

necessary

 

to

 

repair

 

the

 

hose

 

breakaway

 

and/or

 

adjust

 

the

 

position

 

of

 

the

 

breakaway

 

magnetic

 

sensor.

 

To

 

clear

 

the

 

error

 

message,

 

it

 

is

 

necessary

 

to

 

turn

 

the

 

counter

 

power

 

off

 

and

 

on.

 

Call

 

an

 

authorized

 

service

 

centre.

 

E70

 

NFAT

 

Mass

 

meter

 

failure

 

The

 

mass

 

meter

 

does

 

not

 

response

 

Check

 

the

 

mass

 

meter

 

connection.

 

Check

 

the

 

settings

 

of

 

the

 

mass

 

meter

 

communication

 

parameters.

 

Turn

 

the

 

dispenser

 

power

 

off

 

and

 

on.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E71

 

NFAT

 

Communication

 

error

 

with

 

mass

 

meter

 

The

 

mass

 

meter

 

does

 

not

 

response

 

Check

 

the

 

mass

 

meter

 

connection.

 

Check

 

the

 

settings

 

of

 

the

 

mass

 

meter

 

communication

 

parameters.

 

Turn

 

the

 

dispenser

 

power

 

off

 

and

 

on.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E72

 

NFAT

 

Internal

 

mass

 

meter

 

error

 

Follow

 

the

 

documentation

 

for

 

the

 

mass

 

meter

 

used.

 

E73

 

NFAT

 

Mass

 

meter

 

reset

 

error

 

Unsuccessful

 

meter

 

reset

 

before

 

delivery.

 

The

 

error

 

can

 

be

 

caused

 

by

 

the

 

product

 

flow

 

at

 

the

 

idle

 

status

 

before

 

start

 

of

 

delivery.

 

Check

 

the

 

dispenser's

 

internal

 

pressure

 

pipes.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E74

 

NFAT

 

Mass

 

meter

 

configuration

 

error

 

The

 

meter

 

configuration

 

does

 

not

 

meet

 

the

 

requirements

 

of

 

the

 

meter.

 

Mass

 

meter

 

configuration

 

is

 

required.

 

Turn

 

the

 

dispenser

 

power

 

off

 

and

 

on.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E75

 

NFAT

 

Mass

 

meter

 

zero

 

point

 

setting

 

error

 

The

 

current

 

value

 

of

 

the

 

meter

 

zero

 

point

 

does

 

not

 

match

 

the

 

value

 

stored

 

in

 

the

 

counter.

 

It

 

is

 

necessary

 

to

 

set

 

the

 

zero

 

point

 

of

 

the

 

meter.

 

Turn

 

the

 

dispenser

 

power

 

off

 

and

 

on.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

E76

 

NFAT

 

Damaged

 

stored

 

value

 

of

 

the

 

meter

 

zero

 

point

 

The

 

CRC

 

stored

 

values

 

of

 

the

 

meter

 

zero

 

point

 

do

 

not

 

match.

 

It

 

is

 

necessary

 

to

 

set

 

the

 

zero

 

point

 

of

 

the

 

meter.

 

Turn

 

the

 

dispenser

 

power

 

off

 

and

 

on.

 

If

 

the

 

fault

 

persists,

 

call

 

an

 

authorized

 

service

 

centre.

 

Содержание OCEAN TOWER Series

Страница 1: ...ersInstalRev10 docx Revision Date revision 10 January 2022 Number of pages 173 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 42...

Страница 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Страница 3: ...ENSERS 32 2 5 1 SHARK JUNIOR dispensers 34 2 5 2 SHARK JUNIOR LPG dispensers 36 2 5 3 SHARK JUNIOR AdBlue dispensers 37 2 5 4 SHARK ECONOMY dispensers 39 2 5 5 SHARK ECONOMY LPG dispensers 41 2 5 6 SH...

Страница 4: ...ty line STOP button 107 3 5 7 Regulation of valves in pressure sections outside dispenser CNG module 107 3 5 8 Collective signal of the dispenser defect Collective Alarm CNG 108 3 5 9 Cable characteri...

Страница 5: ...3 6 Vapour recovery system test 144 5 3 7 Temperature volume compensation ATC 147 5 3 8 Dispenser operating modes 148 5 3 9 Air separation sensor VRS1 G ZE 2063 149 5 3 10 Preset keypad 149 5 3 11 MAX...

Страница 6: ...where you can find plans of foundations electrical connections and Ex zones for all types of dispensers described in this manual Keep this manual together with documents IN041 IN043 and IN44 throughou...

Страница 7: ...N TOWER LPG dispensers 2 5 17 OCEAN TOWER AdBlue dispensers 2 5 18 OCEAN TOWER WSE dispensers 2 5 19 OCEAN TOWER CNG dispensers 2 5 20 Combined OCEAN TOWER dispensers with LPG module 2 5 21 Combined O...

Страница 8: ...tutory requirements that regulate the assembly and use of dispensers Failure to meet these requirements may create a dangerous situation and or result in dispenser damage NOTE Items stated together wi...

Страница 9: ...and forms and integral part of dispenser accessories The user is fully responsible for using of this manual all operations not described herein shall be considered forbidden The attendant performing s...

Страница 10: ...erefore tanks and pipelines must be cleaned and fuel must be checked for cleanliness before commissioning Filter clogging in a dispenser cannot be considered a reason for warranty repair An inspection...

Страница 11: ...sible process of diesel paraffination The EN 590 standard specifies a prescribed quality of diesel oil It also specifies a distillation curve burning point sulphur content obligatory content of FAME F...

Страница 12: ...r LPG are used at flange connections Gaseous LPG influences human organism as a slight narcotic Inhalation of gaseous LPG for a certain time causes headache nausea faintness reduction of vigilance and...

Страница 13: ...is a solution of water detergents ethanol and other admixtures A percentage content of individual components in the agent may differ However a maximum content of ethanol in the agent is limited to 85...

Страница 14: ...id fuels gasoline diesel LPG E85 technical liquids WSE and AdBlue and gas CNG may only be stored in tanks and containers compatible with these liquids and gases Locations requiring higher carefulness...

Страница 15: ...e a clear warning to prevent it from being accidentally switched on It is not allowed to turn on the dispenser before it is checked and approved by an authorized technician This authorization is subje...

Страница 16: ...ured against spontaneous setting in motion A carbon dioxide extinguisher or dry powder extinguisher with a filling of at least 6 kg must be located at each device The device that is out of order must...

Страница 17: ...vers of the dispenser not to cause any injury of him nor a casual customer While handling of electrical components he she must ensure safe disconnecting of electrical energy supply Only approved compo...

Страница 18: ...shing your eyes with running water for at least fifteen minutes Removal of contact lenses after eye injury may only be carried out by a trained specialist If irritation persists seek medical advice Sk...

Страница 19: ...th cold water do not lubricate it cover it with a sterile bandage and provide medical attention Do not remove the clothing In the case of the ignition of clothes do not run extinguish with water blank...

Страница 20: ...ge and regularly checked for leakage If any other manufacturer s tank for AdBlue liquid is located at the fuel station resolve any questions with this manufacturer in terms of filling emptying cleanin...

Страница 21: ...his is a time tested and worldwide accredited type of hydraulics with a high reliability and a long service life The pumping monoblock is equipped with an input and output washable stainless steel fil...

Страница 22: ...e life The two channel TATSUNO pulse generator is mounted on a piston meter or it is its integral part The measuring unit consists of a piston meter a filter a separator a liquid phase check valve and...

Страница 23: ...ere it is delivered into the AdBlue tank in the vehicle The delivery hoses are made of high quality chemically resistant rubber in an antistatic design the same type of a delivery hose as for LPG deli...

Страница 24: ...hose on both sides in forcible tension stress with following disconnection The delivery hose ends with a delivery nozzle The pressure section of the CNG dispenser may be further equipped with a heat s...

Страница 25: ...able 7 devices 1 to 9 was carried out by procedures B type examination D quality assurance of the production process according to the Government Decree No 120 2016 Coll which stipulates technical requ...

Страница 26: ...SUD Czech s r o Novodvorsk 994 142 21 Prague 4 Each dispenser is subjected to electrical tests connection integrity insulation resistance high voltage test end cap resistance to the earthing point of...

Страница 27: ...30V 10 50Hz max 300VA Pump electric motor 3x400V 230V 50Hz 0 75kW 1410 rpm Electro magnetic valves Proportional 24V DC max 1A Flow rate range Qmax Qmin must be 10 1 Data transmission ofthe entireconte...

Страница 28: ...imum flow to 10 L min When the Elaflex hose is installed then MMQ 2L if the IVGBLUEhose is installed MMQ 5L Data transmission ofthe entire contents of the display with the number of digits 7 6 5 5 is...

Страница 29: ...digits 9999 4 or 99999 5 Maximum amount to pay number of digits 999999 6 or 9999999 7 Maximum quantity number of digits 999999 6 or 1999999 6 5 Scale interval kg 0 01 or 0 001 Display type Electronic...

Страница 30: ...ided dispenser right 7 Specifying abbreviation without The dispenser or module for pumping liquid fuels gasoline diesel LPG The LPG liquefied propane butane dispenser or module AdB AdBlue AUS32 reduci...

Страница 31: ...eft or right side of the dispenser concerns SHARK ECONOMY the location of the nameplate which is always closest to product No 1 and nozzle No 1 1A is decisive In the case of a double sided dispenser t...

Страница 32: ...of the combined dispenser one display is designed for pumping liquid fuel and the other for the delivery of the add on module product LPG AdBlue WSE CNG by access to the dispenser double sided dispen...

Страница 33: ...dispensers with non public delivery displays volume only litre display Note Accordingtothedisplayedvalues alldisplayscanbedividedintolitredisplaysandpublicdeliverydisplays Thelitredisplays contain onl...

Страница 34: ...Notes Special models see chap 2 4 can also be produced in a pressure version without pumps S3 where the submersible pump is located in the storage tank and pushes the fuel into the dispenser via a pr...

Страница 35: ...11 SL ZV2 BMP511 SL H ZV2 BMP521 SL UH ZV2 Figure 2 Standard SHARK JUNIOR dispenser models with a nozzle positioned at the front BMP511 SD BMP511 SD H BMP521 SD UH BMP511 SD HS BMP511 SD H HS BMP521 S...

Страница 36: ...1 SL LPG 1 1 1 1 1 50 BMP511 SR LPG 1 1 1 1 1 50 BMP511 SD LPG 2 1 1 1 2 50 Notes The pumping performance depends on the conditions at the station pump distance pump pressure etc The standard pumping...

Страница 37: ...SHARK JUNIOR ADBLUE dispensers are not standardly equipped with heating For the installation of dispensers in an environment where the temperature drops below 5 C it is necessary to equip the dispens...

Страница 38: ...512 SD AdB ZV2 Figure 5 Standard SHARK JUNIOR ADBLUE dispenser models with nozzles positioned at the front ZV2 BMP511 SD AdB BMP511 SD AdB HS BMP512 SD AdB Picture 6 Standard SHARK JUNIOR ADBLUE dispe...

Страница 39: ...2 4 130 80 BMP522 SXD UH H NC 2 2 2 2 2 130 80 Notes Special models see chap 2 4 can also be produced in a pressure version without pumps S3 where the submersible pump is located in the storage tank...

Страница 40: ...S BMP522 SXD UH HS BMP522 SXD UH H HS Figure 7 Standard models of SHARK ECONOMY dispensers two simultaneous deliveries BMP522 SXD NC BMP522 SXD H NCBMP522 SXD UH BMP522 SXD UH H NC BMP522 SXD NC HS BM...

Страница 41: ...L LPG 1 1 2 2 2 35 35 BMP522 SXD LPG 2 2 2 2 4 50 50 BMP522 SXD LPG 2 1 2 2 4 35 35 BMP522 SXD LPG ZV2 2 2 2 2 2 50 50 BMP522 SXD LPG ZV2 2 1 2 2 2 35 35 Notes The pumping performance depends on the c...

Страница 42: ...th heating For the installation of dispensers in an environment where the temperature drops below 5 C it is necessary to equip the dispenser at the customer s request by heating the hose nozzle boot a...

Страница 43: ...ual revision 10 January 2022 43 BMP512 SXD AdB BMP512 SXD AdB HS Figure 10 Standard SHARK ECONOMY ADBLUE models two simultaneous deliveries BMP512 SXD AdB NC BMP512 SXD AdB NC HS Figure 11 Standard SH...

Страница 44: ...Die 2 2 2 2 4 2 2 40 40 10 BMP522 SXD H AdB Die 2 2 2 2 4 2 2 80 40 10 Notes COMBINED SHARK ECONOMY dispensers are not standardly equipped with heating For the installation of dispensers in an enviro...

Страница 45: ...Fuel Dispensers TATSUNO EUROPE Installation and User Manual revision 10 January 2022 45 BMP522 SXD AdB Die BMP522 SXD AdB Die HS Figure 12 Standard COMBI SHARK ECONOMY models...

Страница 46: ...2 4 the performance of the diesel hoses can be increased to a high performance of 70 to 90 L min H or ultra high performance from 120 to 150 L min UH When using a special meter LOBE the pumping perfo...

Страница 47: ...BMP4012 OED BMP4024 OED BMP4036 OED BMP4048 OED BMP40510 OED Figure 13 Overview of standard OCEAN EURO models in basic design Design variant WAVE BMP4012 OED WAVE Design variant CUBE BMP4012 OED CUBE...

Страница 48: ...OED LPG 2 2 2 2 2 2x50 BMP4022 OED LPG HR 2 2 2 2 2 2x50 BMP4022 OEL R LPG 2C 1 2 2 2 2 2x50 BMP4034 OED LPG 4C 2 3 4 4 4 2x50 2x35 Notes The pumping performance depends on the conditions at the stat...

Страница 49: ...ision 10 January 2022 49 BMP4012 OED LPG BMP4022 OED LPG BMP4034 OED LPG 4C Figure 16 Overview of standard OCEAN EURO LPG models without hose reels BMP4012 OED LPG HR BMP4022 OED LPG HR Figure 17 Over...

Страница 50: ...ispenser 1 single sided 2 double sided Number of pressure inputs Number of meters number of measuring systems Number of delivery hoses Number of main displays number of simultaneous deliveries Filling...

Страница 51: ...nstallation and User Manual revision 10 January 2022 51 BMP4012 OED AdB Figure 19 Overview of standard OCEAN EURO ADBLUE dispensers BMP4012 OED AdB T250 Figure 20 Model of OCEAN EURO ADBLUE dispenser...

Страница 52: ...ispenser model Access to dispenser 1 single sided 2 double sided Number of pressure inputs Number of meters number of measuring systems Number of delivery hoses Number of main displays number of simul...

Страница 53: ...Installation and User Manual revision 10 January 2022 53 BMP4012 OED WSE Figure 22 Overview of standard OCEAN EURO WSE dispensers BMP4012 OED AdB T250 Figure 23 Model of OCEAN EURO ADBLUE dispenser w...

Страница 54: ...ce kg min BMP40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG...

Страница 55: ...tion and User Manual revision 10 January 2022 55 BMP40x2 OED CNG BMP40x4 OWD CNG Figure 24 Overview of standard OCEAN EURO CNG dispensers BMP40x4 OED CNG 4C HE Figure 25 Model of OCEAN EURO CNG dispen...

Страница 56: ...of delivery hoses is 20 L min List of standard OCEAN SMART WSE models Model of dispenser Access to dispenser 1 single sided 2 double sided Number of pressure inputs Number of meters number of measurin...

Страница 57: ...ltaneous deliveries Filling performance kg min BMP40x1 OSL R CNG 1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG...

Страница 58: ...SUNO EUROPE a s www tatsuno europe com 58 BMP40x2 OSD CNG BMP40x2 OSD CNG H BMP40x2 OSD CNG H H BMP40x4 OSD CNG BMP40x4 OSD CNG H BMP40x4 OSD CNG H H Figure 27 Overview of standard OCEAN SMART CNG mod...

Страница 59: ...ormance of the diesel hoses can be increased to a high performance of 70 to 90 L min H or ultra high performance from 120 to 150 L min UH When using a special meter LOBE the pumping performance can be...

Страница 60: ...SUNO EUROPE a s www tatsuno europe com 60 BMP4012 OWD BMP4024 OWD BMP4036 OWD BMP4048 OWD BMP40510 OWD modular version BMP40510 OWD in line version 2021 Figure 28 Overview of standard OCEAN TOWER mode...

Страница 61: ...2 1 2 2 2 2x35 BMP4012 OWD LPG HR 2 1 2 2 2 2x35 BMP4022 OWD LPG 2 2 2 2 2 2x50 BMP4022 OWD LPG HR 2 2 2 2 2 2x50 BMP4022 OWL R LPG 2C 1 2 2 2 2 2x50 BMP4022 OWL R LPG 2C HR 1 2 2 2 2 2x50 BMP4034 OW...

Страница 62: ...with free hanging hoses BMP4012 OWD LPG HR BMP4022 OWD LPG HR two independent deliveries BMP4034 OWD LPG HR 4C four independent deliveries Figure 30 Overview of standard OCEAN TOWER LPG dispensers wit...

Страница 63: ...main displays number of simultaneous deliveries Filling performance kg min BMP4011 OWL R AdB 1 1 1 1 1 40 10 BMP4012 OWD AdB 2 1 2 2 2 40 10 BMP4022 OWL R AdB 1 2 2 2 1 40 10 BMP4024 OWD AdB 2 2 4 4...

Страница 64: ...model without internal heating BMP4012 OWD AdB T250 BMP4024 OWD AdB T500 Picture 34 OCEAN TOWER ADBLUE dispenser model with internal heating and storage tank 250L or 500L BMP4012 OWD AdB T250 NoHeat...

Страница 65: ...g hoses is 20 L min List of standard OCEAN TOWER WSE stand models Model of dispenser Access to dispenser 1 single sided 2 double sided Number of pressure inputs Number of meters number of measuring sy...

Страница 66: ...TATSUNO EUROPE a s www tatsuno europe com 66 BMP4012 OWD AdB T250 BMP4024 OWD AdB T500 Picture 37 OCEAN TOWER WSE special models of dispenser with suction pump and storage tank 250L or 500L...

Страница 67: ...BMP40x1 OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2...

Страница 68: ...TATSUNO EUROPE a s www tatsuno europe com 68 BMP4024 OWD CNG 4C HE Picture 39 OCEAN TOWER CNG dispenser with four independent dispensing hoses NGV1 and hose extender HE...

Страница 69: ...OWL R LPG 1 2 2 1 1 1 BMP4011 OWL R 2C MOD4011 OWL R LPG 1 2 2 1 1 2 BMP4012 OWD MOD4012 OWD LPG 2 2 4 2 2 2 BMP4012 OWD 4C MOD4012 OWD LPG 2 2 4 2 2 4 BMP4022 OWL R MOD4011 OWL R LPG 1 3 3 1 1 1 BMP4...

Страница 70: ...2 OWD LPG HR BMP4024 OWD MOD4012 OWD LPG BMP4024 OWD MOD4012 OWD LPG HR BMP4036 OWD MOD4012 OWD LPG BMP4036 OWD MOD4012 OWD LPG HR BMP4048 OWD MOD4012 OWD LPG BMP4048 OWD MOD4012 OWD LPG HR Figure 40...

Страница 71: ...3 3 1 1 1 BMP4022 OWL R 2C MOD4011 OWL R AdB 1 3 3 2 1 2 BMP4024 OWD MOD4012 OWD AdB 2 3 6 4 2 2 BMP4024 OWD 4C MOD4012 OWD AdB 2 3 6 4 2 4 BMP4033 OWL R MOD4011 OWL R AdB 1 4 4 3 1 1 BMP4033 OWL R 2C...

Страница 72: ...uno europe com 72 BMP4012 OWD MOD4012 OWD AdB BMP4024 OWD MOD4012 OWD AdB BMP4036 OWD MOD4012 OWD AdB BMP4048 OWD MOD4012 OWD AdB Figure 41 Overview of standard OCEAN TOWER COMBI ADB dispensers with h...

Страница 73: ...ary 2022 73 BMP4012 OWD MOD4012 OWD AdB NoHeat BMP4024 OWD MOD4012 OWD AdB NoHeat BMP4036 OWD MOD4012 OWD AdB NoHeat BMP4048 OWD MOD4012 OWD AdB NoHeat Figure 42 Overview of OCEAN TOWER COMBI ADB disp...

Страница 74: ...P4011 OWL R 2C MOD4011 OWL R WSE 1 2 2 1 1 2 BMP4012 OWD MOD4012 OWD WSE 2 2 4 2 2 2 BMP4012 OWD 4C MOD4012 OWD WSE 2 2 4 2 2 4 BMP4022 OWL R MOD4011 OWL R WSE 1 3 3 1 1 1 BMP4022 OWL R 2C MOD4011 OWL...

Страница 75: ...OPE Installation and User Manual revision 10 January 2022 75 BMP4012 OWD MOD4012 OWD WSE BMP4024 OWD MOD4012 OWD WSE BMP4036 OWD MOD4012 OWD WSE BMP4048 OWD MOD4012 OWD WSE Figure 43 Overview of OCEAN...

Страница 76: ...module hose Number of main displays number of simultaneous deliveries BMP4011 OWL R MOD40x1 OWL R CNG 1 2 2 1 1 1 BMP4012 OWD MOD40x2 OWD CNG 2 2 4 2 2 2 BMP4022 OWL R MOD40x1 OWL R CNG 1 3 3 1 1 1 B...

Страница 77: ...WD CNG BMP4036 OWD MOD40x2 OWD CNG BMP4048 OWD MOD40x2 OWD CNG Figure 44 Overview of OCEAN TOWER COMBI CNG dispensers x 1 2 3 is the number of the CNG pressure inputs BMP4048 OWD MOD40x4 OWD CNG H H F...

Страница 78: ...er of simultaneous deliveries BMP4011 OWL R MOD4011 OWL R LPG MOD40x1 OWL R CNG 1 3 3 1 1 1 2 BMP4012 OWD MOD4012 OWD LPG MOD40x2 OWD CNG 2 3 6 2 2 2 4 BMP4022 OWL R MOD4011 OWL R LPG MOD40x1 OWL R CN...

Страница 79: ...22 79 BMP4012 OWD MOD4012 OWD LPG MOD40x2 OWD CNG BMP4024 OWD MOD4012 OWD LPG MOD40x2 OWD CNG BMP4036 OWD MOD4012 OWD LPG MOD40x2 OWD CNG BMP4048 OWD MOD4012 OWD LPG MOD40x2 OWD CNG Figure 46 Overview...

Страница 80: ...er of simultaneous deliveries BMP4011 OWL R MOD4011 OWL R AdB MOD40x1 OWL R CNG 1 3 3 1 1 1 2 BMP4012 OWD MOD4012 OWD AdB MOD40x2 OWD CNG 2 3 6 2 2 2 4 BMP4022 OWL R MOD4011 OWL R AdB MOD40x1 OWL R CN...

Страница 81: ...22 81 BMP4012 OWD MOD4012 OWD AdB MOD40x2 OWD CNG BMP4024 OWD MOD4012 OWD AdB MOD40x2 OWD CNG BMP4036 OWD MOD4012 OWD AdB MOD40x2 OWD CNG BMP4048 OWD MOD4012 OWD AdB MOD40x2 OWD CNG Figure 47 Overview...

Страница 82: ...ber of products number of pumps or inputs Total number of meters number of measuring systems Number of delivery hoses dispenser hose module hose Number of main displays number of simultaneous deliveri...

Страница 83: ...ber of measuring systems Number of delivery hoses dispenser hose module hose Number of main displays number of simultaneous deliveries BMP4011 OWL R LPG MOD40x1 OWL R CNG 1 2 2 1 1 2 BMP4011 OWL R LPG...

Страница 84: ...6 IP67 26 Lock 3 Pumping monoblock 15 Display mask plate 27 Display 4 Pump pulley 16 Vapour recovery pump 28 Door left 5 Air separation sensor 17 Vapour recovery pump motor 29 Door right 6 Pulser puls...

Страница 85: ...r pulse generator 12 Nozzle cover K3 LPG module roof 6 Output ball valve gas 13 Gaseous phase separator K4 LPG module door 7 Differential valve 14 Filter K5 Front column LPG 2 6 3 REDUCTION AGENT AUS...

Страница 86: ...or 4 Pulser pulse generator K4 Column lid rear combi 5 Electro magnetic valve K5 Front column combi 2 6 5 COMPRESSED NATURAL GAS CNG DISPENSER MODULE Figure 55 Basic parts of the WSE dispensing module...

Страница 87: ...y and safety according to WELMEC 10 5 and European standards for equipment located in potentially explosive areas EN 13617 1 EN 14678 1 EN IEC 60079 0 and EN ISO 80079 36 is contained in the nameplate...

Страница 88: ...Range of delivered liquid medium or gas temperature for which the dispenser was designed and approved Ambient temperature range Range of ambient temperature for which the dispenser was designed and ap...

Страница 89: ...ing If the transport is ensured by TATSUNO EUROPE a s it shall transport the product to an agreed place The manufacturer has sufficient knowledge about the method of handling and transport If the tran...

Страница 90: ...ehicle Loading from the rear of the vehicle is dangerous and can damage the vehicle the stand and injure people see figure below Picture 65 Permitted and forbidden direction of loading and unloading o...

Страница 91: ...as best as possible Therefore it is suggested to Secure the access to the refilling position in straight direction Install the dispenser onto an elevated refuge with the following parameters refuge el...

Страница 92: ...e 1 of the filling end piece during delivery 7 projection of the dangerous zone border zone 2 of the CNG dispenser CAUTION LPG LPG dispensers modules are standardly equipped with a breakaway coupling...

Страница 93: ...ion gasoline etc the dispenser zones are also regulated by the EN 13617 1 standard for LPG dispensers liquefied propane butane the EN 14678 1 standard Drawings of the zones created by the dispenser ar...

Страница 94: ...tall the AdBlue near the fuel dispenser or other equipment that generates the zone it is necessary to take into account which parts of the dispenser can be installed immersed in the danger zone and wh...

Страница 95: ...ser from the vehicle arrival direction see Figure 1 3 3 4 DISPENSER DISTANCE FROM A TANK FUEL TANK The manufacturer recommends that the maximum distance of dispensers from storage tanks gasoline diese...

Страница 96: ...heck valve must not be installed if a suction basket has been already equipped with a check valve see Picture 72 CAUTION B D If the dispenser is connected to an aboveground storage tank it is necessar...

Страница 97: ...d then into its surroundings in case of leakage or blockage of the check valve when the dispenser is out of operation it is necessary to connect the outlet of the pumping monoblock separator to the st...

Страница 98: ...hrough gauges and control valves into delivery hoses and nozzles CAUTION According to the European standard EN 13617 1 the dispenser connected to the pressure system must be equipped with a breakaway...

Страница 99: ...Fuel Dispensers TATSUNO EUROPE Installation and User Manual revision 10 January 2022 99...

Страница 100: ...line NOTE The G 1 lid is included in the dispenser delivery The suction line must be terminated by the G1 internal thread CAUTION LPG LPG extrusion from the dispenser and pipeline e g while removing t...

Страница 101: ...sufficient length each end at least 3 m above ground In terms of used voltage and function the cables may be divided into power supply and signal cables Power cables supply of pump and vacuum pump el...

Страница 102: ...oard This circuit breaker serves as a switch and includes both short circuit and thermal fuse After installation into the door of the switchboard this circuit breaker can be supplemented with a contro...

Страница 103: ...3 Gb Ex II 2G Ex e IIC T3 Gb EPT 16 ATEX 2476X EUM1 12 ATEX 0744 NOTICE When the electric motor is connected check the correct direction of rotation The correct direction of rotation is indicated by t...

Страница 104: ...ruptible Power Supply Very frequent phenomena in the electricity network are power failures strong interference or voltage fluctuations in voltage peaks especially in winter season All such phenomena...

Страница 105: ...hing phase 5 S4 black 4 switching phase 4 S3 black 3 switching phase 3 S2 black 2 switching phase 2 S1 black 1 switching phase 1 PE yellow green protection wire NOTE Relays in the dispenser are used f...

Страница 106: ...protocol However it is possible on customer s demand to add a data converter to the dispenser counter which will concert the PDE data line to a line of another type and communication protocol e g PUM...

Страница 107: ...the security line Identification of wires in the H05VV5 F 3x1 5 cable identification colour description ST black2 STOP signal ST black1 STOP signal PE yellow green protection wire 3 5 7 REGULATION OF...

Страница 108: ...interrupted and the display shows the defect code which corresponds to the defect type e g broken hose leak in the vehicle storage tank meter failure etc At the same time the relay of a collective dis...

Страница 109: ...overvoltage protection is used which diverts energy of the overvoltage pulse to the grounding wire thus protecting the device The dispenser manufacturer recommends protecting the main switchboard or t...

Страница 110: ...sion CRC after powering on or in parameter P05 1 version P05 2 CRC after powering on or in parameter P51 CRC P53 version after powering on or in parameter P05 1 version P05 2 CRC after powering on or...

Страница 111: ...sic operating parameters of the dispenser The access to the Manager mode is protected by password 4 1 1 DESCRIPTION OF PDERT 5O REMOTE CONTROLLER The keyboard of the PDERT 5O remote manager s controll...

Страница 112: ...olume Keys 0 1 9 can be used just like the pre set keypad to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the...

Страница 113: ...values of all parameters listed below see table below Parameter Description P00 Non resettable quantity totalizers volume or weight P01 Daily quantity totalizers volume or weight P02 Daily amount tota...

Страница 114: ...otalizers reset P01 and P02 P16 P19 not used P20 Error message codes history P21 Error message codes statistics of filling point A P22 Error message codes statistics of filling point B P23 Error messa...

Страница 115: ...rs can be reset at any time using parameter P15 see description below Parameter Meaning P01 1 quantity of the fuel delivered by hose 1 in centilitres x 0 01L P01 2 quantity of the fuel delivered by ho...

Страница 116: ...03 parameter are valid in the dispenser manual mode only If the dispenser is connected to the central control system of the fuel station then the fuel unit price is set directly by the control system...

Страница 117: ...EDPS with address 3 If not present is displayed P05 11 CRC of the program of the pressure sensors unit PDEDPS with address 4 If not present is displayed NOTE Metrologically relevant data P05 1 and P05...

Страница 118: ...f filling point B E80 2 P10 12 Main electromechanical totalizers unit Master of filling point B E82 1 P10 13 Auxiliar electromechanical totalizers unit Slave of filling point B E82 2 P10 14 Main displ...

Страница 119: ...blocked by switch SW1 2 4 1 16 EXPORT OF PARAMETERS P13 To export the counter parameters from the memory to the memory card SD card press the E key enter 1 and confirm with the E key Before running th...

Страница 120: ...ive numbers of individual error messages for a given filling point The first line of the display shows the error message code and the second line the frequency of the error After switching to paramete...

Страница 121: ...last fuelling history at filling point A the display shows the last fuelling transaction The transaction price with the parameter number flashes on the unite price display After pressing the key the p...

Страница 122: ...or etc appears After pressing the E key the date and time of the correction factor change will appear on the display Parameter Meaning P 30 00 Last record of the correction factor changes P 30 01 Penu...

Страница 123: ...rature sensor unit Entry into the service mode and removal of the metrological seal is necessary for storage 4 1 25 CONTROL MODE CHANGES HISTORY P32 The parameter allows to display the last 20 records...

Страница 124: ...er switching to parameter P35 the display shows the average volume ratio value for filling point A P35 A The quantity display line shows the vapour fuel ratio in percent with one decimal place After p...

Страница 125: ...an 100 it means that the feedback has reduced the flow of petrol vapor Without feedback the vapour fuel ratio achieved would then be greater than 100 If the value is higher than 100 it means that the...

Страница 126: ...y quantity totalizers P02 quantity totalizers only 03 Product unit prices in manual mode P03 04 Current time and date P04 05 Program version and CRC check sums P05 06 Error message code history P20 10...

Страница 127: ...3 Auxiliary displaying unit Slave E81 10 4 Electromechanical totalizers unit E82 10 5 Temperature sensors unit PDEINP E83 10 6 Mass meter E84 NOTESerial numbers of peripheral units are checked before...

Страница 128: ...y totalizers P00 02 Daily quantity totalizers P01 P02 03 Product unit prices in manual mode P03 04 Current time and date P04 backup time max 5 days 05 Program version and CRC check sums P05 06 Error m...

Страница 129: ...ispensingauthorizationisusedtocalculatethetotal dispensed sum Prices saved in the parameter P03 are non functional How to set the fuel price in a manual mode The price change can only be made between...

Страница 130: ...r vice versa when the dispenser is in a manual mode and must be connected to the control system How to change the working mode Turn the power supply of the dispenser counter off and on During the coun...

Страница 131: ...loves during normal maintenance and during deliveries In case of skin contact wash the affected area as soon as possible with soap and water In case of eye contact etc seek medical attention During de...

Страница 132: ...ly authorized service company The operator is responsible for keeping the AdBlue dispenser in its original and safe condition any defect or unusual phenomenon must be immediately reported to a service...

Страница 133: ...zation about the defect of abnormality during operation and immediately decommission the device in case of danger of default CAUTION CNG It is forbidden to smoke and use open fire in the immediate vic...

Страница 134: ...t the multimedia display During the time delay the displays show the filling point to which the display is connected A B C or D and the time in seconds remaining until the electronic dispenser counter...

Страница 135: ...mass meter Subsequently the counter waits for a response from the mass meter It then ones send information that the zero point was set with the message done or was not set with the message fail Don t...

Страница 136: ...ccording parameter P44 Mass flow cut off 0 055 kg min Volume flow cut off 0 01 L min Flow dumping 0 s Update rate 100 Hz Slot address register Addresses of registers in order mass flow volume flow den...

Страница 137: ...rocedure see later Serial number Number stored during Serial number storage procedure NOTICE CNG After start up of calculator TBELTM and before every delivery transaction are checked values of the reg...

Страница 138: ...tions usedeliverystop nozzles withasafetyshutter Usingthecontrol lever the flow rate can be controlled until it stops In the basic version the delivery nozzle is supplied with a lever lock At customer...

Страница 139: ...d with a two stage solenoid valve NOTICEPursuant to EN 14678 1 2013 article 4 5 8 LPG dispensers designed for self service operation must be equipped with a dead man button START button to ensure that...

Страница 140: ...ations must be in addition to the START button also equipped with a safety STOP button and the delivery nozzle position sensor see EN 14678 1 art 4 5 6 Unattended fuel stations must be equipped with a...

Страница 141: ...irst pressure section and the pressure storage tank of the vehicle is filled with compressed natural gas In the moment whenthedeliveryspeeddecreasesunderthedefinedlimit the electronic counter automati...

Страница 142: ...dispensers must be equipped with a breakaway coupling located between the delivery nozzle and the dispenser This breakaway coupling disconnects the gas flow rate at both ends in case of emergency The...

Страница 143: ...equipped with electromechanical totalizers for monitoring the total amount of fuel flown through each delivery hose Totalizers are located on the dispenser display Each delivery hose or nozzle has one...

Страница 144: ...hree years NOTICE In case of suspicion of malfunctioning of the recovery or detection of malfunctioning of the signalling the operator is obliged to notify this fact immediately to the service organiz...

Страница 145: ...ing the E key again The value of the air volume after the test is read from the gas meter and the volume of air that flowed during the test is calculated Test evaluation The equations apply to determi...

Страница 146: ...our recovery valve 3 Press the 8 key on the manager or service remote controller The screen 1 will appear on the display see previous test 4 Press the E key The vacuum pump starts for the time set in...

Страница 147: ...Volume values for selected liquid fuels at temperature T and dispensed volume Vn 100 L Liquid 0 kg m3 T 20 C T 10 C T 0 C T 15 C T 30 C T 50 C Natural 91 Regular Unleaded 737 104 26 103 05 101 84 100...

Страница 148: ...The control unit sends afuelunitprice amaximumamount volumeofdelivery andallows delivery Thedisplayofthedispenser will reset approx 2 seconds after removing the nozzle and the pump motor switches on...

Страница 149: ...n line is broken The VRS1 G sensor is activated and the BL input goes to the active state then for a test time of 1 to 50 seconds standard 10 sec the counter performs the first test cycle i e closes t...

Страница 150: ...target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for 10 a Press the 5 key twice on the 4 key preset keypad b Press...

Страница 151: ...m flow Qmax given by the pump used flows through the delivery hose The limited flow value Qlim can be set for each delivery hose using the counter parameter 5 3 12 MIN BUTTON FOR DELIVERY CONTROL For...

Страница 152: ...during delivery if the temperature compensation function is activated for the delivered product High and low output signals fuel flow it appears automatically before or during delivery when the MAX bu...

Страница 153: ...off the backup UPS located in the booth by a switch located at the rear panel the green LED on the UPS turns off After switching off the power supply of the electronics in the fuel station switchboard...

Страница 154: ...e delivery hoses In case of mechanical damage to the delivery hose ensure its immediate replacement check the function of the door locks and the mechanism for hanging the delivery nozzle care for exte...

Страница 155: ...ed by employees with appropriate authorization PRINCIPLES OF LPG DISPENSING MODULE INSPECTIONS Inspections of devices reservoirs pipeline systems and dispensers are performed on dates defined by the o...

Страница 156: ...ainless covers Wash them with warm water at least twice per month according to the level of fouling At least once a month or after each higher surface fouling with fuels wash them with warm water thor...

Страница 157: ...nd AdBlue FM 1022 can be turned through 17 holes in both directions The difference of precision between two adjacent holes is 0 08 The wheel can be fixed alsoinapositionbetweenholes i e thedifferenceo...

Страница 158: ...r of pulse generator phases for filling 1L of fuel default parameter value is 400 which corresponds to 400 pulse phases per litre 100 pulses per litre The parameter value can only be changed after swi...

Страница 159: ...cover and sealed Calibration of the meter at the dispenser equipped with temperature compensation of the volume If temperature correction of the volume is activated in the dispenser then a special ser...

Страница 160: ...ce level of the counter configuration is entered and the parameter value in M6 P15 is changed to 1 or 2 thus activating the automatic meter calibration mode 3 Accurate delivery into the calibrated ves...

Страница 161: ...nect the auxiliary pump b calibrate the main meter as described in 6 1 3 c connect the auxiliary pump d calibrate the auxiliary meter settings as described in 6 1 3 NOTE The auxiliary pump can be disc...

Страница 162: ...inlet ball valve 1 Connect nozzle 3 to the auxiliary connector for return LPG outlet 4 and open auxiliary ball valve 5 located behind the check valve 6 Open the LPG vapour phase outlet ball valve 2 3...

Страница 163: ...eset but the pump does not start This means that the dispenser electric motor has not been started The cause may be the power supply circuit breaker that is located in the main switchboard or the elec...

Страница 164: ...failure longer than 3 5 periods t 100ms It is necessary to turn off the dispenser counter power source for approx 10 seconds and then turn the source back on STOP LOCK Maximum time to interrupt delive...

Страница 165: ...k the function of the data converter Check by a monitor the course of communication E20 NFAT Power failure during delivery The last delivery was interrupted abnormally due to a power failure Check the...

Страница 166: ...PUL2 PDEX 2A E43 NFAT Connection error or internal pulse generator error at input PDEX5 PUL3 PDEX 3A E44 NFAT Connection error or internal pulse generator error at input PDEX5 PUL4 PDEX 4A E45 NFAT Co...

Страница 167: ...persists call an authorized service centre E64 NFAT CNG Insufficient pressure rise during temperature compensation test filling Check the pressure system for leaks If the fault persists call an author...

Страница 168: ...The error appears after replacing the PDEDPS unit Peripheral unit serial numbers must be stored Call an authorized service centre E86 NFAT Insufficient LPG pressure difference The pressure difference...