TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
28
Table
10
‐
AdBlue®
dispensers
and
modules
(AUS32)
Pumping
performance
Standard
LV
(passenger
cars)
*
Maximum
flow
rate
Q
max
[L/min]
40
10
Minimum
flow
rate
Q
min
[L/min]
4
4
Lowest
metering
MMQ
[L]
2
/
5
**
2
/
5
**
Maximum
working
pressure
[MPa]
0.3
Minimum
working
pressure
[MPa]
0.1
Maximum
unit
price
(number
of
digits)
9999(4)
or
99999(5)
***
Maximum
amount
to
pay
(number
of
digits)
999999(6)
or
9999999(7)
***
Maximum
volume
(number
of
digits)
999999(6)
or
1999999(6.5)
***
Scale
interval
[L]
0.01
Display
type
Electronic
Type
of
delivered
fluid
AdBlue®
(32.5%
aqueous
urea
solution
according
to
DIN
70070
and
ISO
22241)
Filtration
of
mechanical
particles
Input
filter
>70µm
Fluid
temperature
range
[°C]
‐
10
to
+30
Ambient
temperature
range
[°C]
‐
20
to
+40
(standard
dispenser
version);
‐
20
to
+50
(enhanced
dispenser
version)
0
to
+40°C
(version
without
heating)
Accuracy
class
0.5
Mechanical
class
M1,
M2
for
counters
PDEX5
and
TBELTx
Electromagnetic
class
E1,
E2
for
the
counter
PDEX5
Humidity
Condensing
Location
Open
Measured
unit
Volume
[L]
or
volume
at
15
°C
[L]
Electronic
counter
TBELTx
PDEX
PDEX5
Program
version
(W&M
check
sum)
1.01
(8CA4)
1.03
(20260)
1.01
(4573),
1.02
(dbd2FFA4)
Calculator
powering
230V
±
10%;
50Hz;
max.
300VA
Electro
‐
magnetic
valves
Proportional
or
two
‐
state;
+
24VDC
/
max.1A
*
The
LV
measuring
system
contains
a
ZVA
AdBlue
delivery
nozzle
that
limits
the
maximum
flow
to
10
L/min
**
When
the
Elaflex
hose
is
installed
then
MMQ
=
2L;
if
the
IVGBLUE
hose
is
installed,
MMQ
=
5L
***
Data
transmission
of
the
entire
contents
of
the
display
with
the
number
of
digits
7/6.5/5
is
only
possible
using
the
extended
communication
protocol
(8/8/6)
Table
11
‐
WSE
(for
dispensing
windshield
washer
fluid)
dispensers
and
modules
Maximum
flow
rate
Q
max
[L/min]
20
Minimum
flow
rate
Q
min
[L/min]
2
Lowest
metering
MMQ
[L]
2
Maximum
working
pressure
[MPa]
0.3
Minimum
working
pressure
[MPa]
0.1
Maximum
unit
price
(number
of
digits)
9999(4)
or
99999(5)
*
Maximum
amount
to
pay
(number
of
digits)
999999(6)
or
9999999(7)
*
Maximum
volume
(number
of
digits)
999999(6)
or
1999999(6.5)
*
Scale
interval
[L]
0.01
Display
type
Electronic
Type
of
delivered
fluid
WSE
(mixture
of
water,
detergents,
and
ethanol)
Filtration
of
mechanical
particles
Input
filter
>70µm
Fluid
temperature
range
[°C]
‐
20
to
+50
Ambient
temperature
range
[°C]
‐
20
to
+40
(standard
dispenser
version);
‐
20
to
+50
(special
dispenser
version)
Accuracy
class
0.5
Mechanical
class
M1,
M2
for
counters
PDEX5
and
TBELTx
Electromagnetic
class
E1,
E2
for
the
counter
PDEX5
Humidity
Condensing
Location
Open
Measured
unit
Volume
[L]
or
volume
at
15
°C
[L]
Electronic
counter
TBELTx
PDEX
PDEX5
Program
version
(W&M
check
sum)
1.01
(8CA4)
1.03
(20260)
1.01
(4573),
1.02
(dbd2FFA4)
Calculator
powering
230V
±
10%;
50Hz;
max.
300VA
Electro
‐
magnetic
valves
Proportional
or
two
‐
state;
+
24VDC
/
max.1A
*
Data
transmission
of
the
entire
contents
of
the
display
with
the
number
of
digits
7/6.5/5
is
only
possible
using
the
extended
communication
protocol
(8/8/6)
Содержание OCEAN TOWER Series
Страница 99: ...Fuel Dispensers TATSUNO EUROPE Installation and User Manual revision 10 January 2022 99...
Страница 171: ...Fuel Dispensers TATSUNO EUROPE Installation and User Manual revision 10 January 2022 171 NOT...
Страница 172: ......