TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
160
The
special
PDEX5
counter
mode
is
used
(M6
‐
P09)
for
automatic
electronic
calibration
of
the
meter
,
in
which
the
correction
factor
of
the
meter
is
automatically
calculated
and
set.
In
this
way,
it
is
also
possible
to
calibrate
dispenser
with
active
temperature
compensation
of
the
volume.
The
automatic
meter
calibration
mode
is
activated
by
parameter
M6
‐
P15.
NOTE
For
dispensers
with
ultra
‐
high
filling
(130
L/min),
where
two
meters
are
used
for
one
dispensing
hose
/
nozzle,
it
is
necessary
to
first
calibrate
the
main
meter
when
setting
parameter
M6
‐
P15
=
1.
The
counter
does
not
start
the
auxiliary
pump
motor
when
calibrating
the
main
meter.
After
calibration
of
the
main
meter,
the
auxiliary
meter
is
calibrated
when
parameter
M6
‐
P15
=
2
is
set.
The
counter
does
not
start
the
main
pump
motor
when
calibrating
the
auxiliary
meter.
The
procedure
for
automatic
electronic
calibration
of
the
meter
is
as
follows:
1)
The
PDEX5
counter
processor
unit
cover
is
de
‐
sealed,
removed
and
switch
SW1
‐
1
is
switched
to
the
OFF
position.
2)
Using
the
PDERT
‐
xS
service
remote
controller
after
entering
the
service
password,
the
service
level
of
the
counter
configuration
is
entered
and
the
parameter
value
in
M6
‐
P15
is
changed
to
1
or
2,
thus
activating
the
automatic
meter
calibration
mode.
3)
Accurate
delivery
into
the
calibrated
vessel
is
performed.
The
vessel
volume
must
be
10L,
20L,
50L,
or
100L.
4)
After
hanging
the
nozzle,
"E
‐
C"
appears
on
the
bottom
line
of
the
display
and
the
counter
waits
for
confirmation
whether
it
should
consider
the
performed
measurement
valid
and
should
calculate
a
new
correction
factor.
5)
After
pressing
the
<E>
key,
a
new
correction
factor
is
calculated
and
saved
automatically.
6)
A
new
accurate
delivery
into
the
calibrated
vessel
is
performed.
7)
If
equality
is
not
achieved
between
the
volume
in
the
vessel
and
the
indicated
volume,
the
calibration
can
be
repeated
according
to
point
4).
8)
If
everything
is
OK,
the
switch
back
to
the
standard
operating
mode
is
performed
by
setting
parameter
M6
‐
P15
to
the
value
0.
9)
Switch
SW1
‐
1
is
switched
to
the
ON
position,
the
processor
unit
is
covered
with
a
cover
and
sealed.
10000
20087
F
384
current
correction
factor
(1.0000)
volume
(20.087L)
current
flowrate
(38.4
l/min)
10000
20087
E
‐
C
current
correction
factor
(1.0000)
volume
(20.087
L)
E
‐
confirm/
C
‐
cancel
9957
20087
new
value
of
the
corr.
factor
0.9957)
volume
(20.087
L)
9957
20000
E
‐
C
current
correction
factor
(0.9957)
volume
(20.000L)
E
–
confirm
/
C
‐
cancel
M6
1
P15
M6
0
P15