5.3.
DISPENSER
OPERATION
NOTICE
The
operator
is
responsible
for
the
operation
of
the
fuel
station
and
it
is
his
duty
to
monitor
the
delivery
of
fuel
and,
in
the
event
that
the
customer
performs
unauthorized
operations
at
the
self
‐
service
dispensers,
he
must
instruct
the
customer
about
proper
handling.
The
operator
is
also
obliged
to
mark
the
risk
area
of
the
fuel
station
with
warning
symbols
(smoking
ban,
ban
on
open
fire,
direction
of
arrival
to
the
dispenser,
etc.).
The
fuel
station
operating
instructions
must
be
freely
accessible
to
the
customer
for
any
information
on
basic
obligations.
5.3.1.
FUEL
(PETROL,
DIESEL
...)
AND
TECHNICAL
LIQUIDS
(WSE,
ADBLUE®)
DELIVERY
Starting
the
dispenser
is
carried
out
by
lifting
the
delivery
nozzle
from
the
nozzle
cover
which
simultaneously
automatically
resets
the
electronic
counter
data.
Then
the
pump
electric
motor
is
started
and
the
fuel
can
be
delivered.
The
delivering
speed
is
controlled
by
the
delivery
nozzle.
Ending
the
delivery
is
performed
by
closing
the
delivery
nozzle
(by
releasing
the
control
lever)
and
its
subsequent
hanging
in
the
nozzle
cover
which
shuts
down
the
pump
electric
motor.
The
quantity
delivered
remains
unchanged
until
the
delivery
nozzle
is
lifted
again
or
until
the
payment.
Fuel
delivery.
The
fluid
measured
by
the
meter
is
delivered
into
the
delivery
hose
and
the
delivery
nozzle
bolted
to
the
end
of
the
hose.
Self
‐
service
fuel
stations
use
delivery
stop
‐
nozzles
with
a
safety
shutter.
Using
the
control
lever,
the
flow
rate
can
be
controlled
until
it
stops.
In
the
basic
version,
the
delivery
nozzle
is
supplied
with
a
lever
lock.
At
customer's
request,
a
delivery
nozzle
is
provided
without
a
lock
where
the
lever
must
still
be
pressed
during
delivery.
When
releasing
the
lever
or
dropping
the
delivery
stop
‐
nozzle
out
of
the
tank
opening,
the
fuel
flow
stops.
The
stop
function
occurs
when
the
tank
is
full
after
the
sensor
has
detected
the
fluid
level,
the
flow
stops
even
when
the
control
lever
is
depressed.
The
safety
function
works,
for
example,
when
the
delivery
nozzle
is
not
properly
handled,
i.e.,
the
discharge
attachment
is
higher
than
15
degrees
from
the
horizontal
plane
upwards,
the
flow
stops
even
when
the
control
lever
is
depressed.
After
the
stop
function
and
the
safety
function
it
is
necessary
to
release
the
control
lever
to
automatically
return
to
the
basic
position.
Table
33
‐
Delivery
nozzle
positions
during
delivery
Correct
position
of
the
delivery
nozzle
during
delivery
The
delivery
nozzle
is
almost
vertical,
the
ball
does
not
prevent
the
passage
of
air
and
the
fuel
flows.
Incorrect
delivery
nozzle
position
The
delivery
nozzle
is
diverted
from
the
horizontal
position,
the
ball
prevents
the
passage
of
air
and
the
fuel
does
not
run
In
various
designs
of
fuel
tank
inlet
ports,
it
is
necessary
to
find
the
optimal
position
of
the
delivery
nozzle
when
the
fuel
still
flows.
Flow
shut
‐
off
may
also
occur
when
the
fuel
flow
from
the
delivery
nozzle
hits
the
wall
of
the
tank
neck.
In
that
case,
it
is
also
necessary
to
find
the
optimal
position.