Fuel
Dispensers
TATSUNO
EUROPE
‐
Installation
and
User
Manual
,
revision
10,
January
2022
159
3)
The
processor
unit
cover
is
de
‐
sealed,
removed
and
switch
SW1
‐
1
is
switched
to
the
OFF
position.
4)
Using
the
service
remote
controller
PDERT
‐
5S,
the
service
mode
of
the
counter
is
entered
by
entering
the
service
password.
The
value
of
the
parameter
is
changed
and
the
service
mode
is
exited.
5)
New
accurate
fuel
delivery
is
performed
into
the
calibrated
vessel
(20L)
6)
If
everything
is
OK
i.e.,
the
indicated
volume
on
the
display
corresponds
to
the
volume
of
the
calibration
vessel,
switch
SW1
‐
1
is
switched
to
the
ON
position,
the
processor
unit
is
covered
with
a
cover
and
sealed.
Calibration
of
the
meter
at
the
dispenser
equipped
with
temperature
compensation
of
the
volume
If
temperature
correction
of
the
volume
is
activated
in
the
dispenser,
then
a
special
service
mode
is
used
to
calibrate
the
meter
(for
PDEX5
parameter
M05
‐
P00
=
6,
for
PDEX
parameter
P60
=
6),
during
which
the
display
shows
as
temperature
‐
corrected
fuel
volume,
as
well
as
the
temperature
uncorrected
fuel
volume
together
with
the
current
fuel
temperature.
The
temperature
‐
uncompensated
volume
data
is
always
used
to
calibrate
the
meter.
Mechanical
or
electronic
calibration
of
the
meter
is
performed
in
the
same
way
as
described
in
the
previous
paragraphs
of
the
chapter.
Table
38
‐
Calibration
table
for
calibrated
vessel
20L
22.48
20.00
1.124
98.14
100
.
00
t
300
compensated
volume
(98.14L)
uncompensated
volume
(100L)
current
fuel
temperature
(30.0°C)