TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
168
Code
of
message
Type
of
message
Cause
of
error
message
Removing
error
message
E80
NFAT
The
display
serial
number
does
not
match
The
serial
number
of
the
display
differs
from
the
stored
one.
Error
message
code
detail:
E80
‐
1
Main
display
serial
number
does
not
match
E80
‐
2
Auxiliar
display
serial
number
does
not
match
The
error
appears
after
replacing
the
display.
Peripheral
unit
serial
numbers
must
be
stored.
Call
an
authorized
service
centre.
E81
NFAT
CNG:
The
serial
number
of
the
auxiliar
display
does
not
match.
The
serial
number
of
the
auxiliar
display
(Slave)
is
different
from
the
stored
one.
The
error
appears
after
replacing
the
display.
Peripheral
unit
serial
numbers
must
be
stored.
Call
an
authorized
service
centre.
E82
NFAT
The
serial
number
of
the
electromechanical
totalizer
unit
does
not
match.
The
serial
number
of
the
electromecha
‐
nical
totalizer
unit
differs
from
the
stored
one.
The
error
appears
after
replacing
the
totalizers
unit.
Peripheral
unit
serial
numbers
must
be
stored.
Call
an
authorized
service
centre.
E83
NFAT
The
serial
number
of
the
PDEINP
temperature
sensors
unit
does
not
match.
The
serial
number
of
the
PDEINP
unit
is
different
from
the
stored
one.
The
error
appears
after
replacing
the
PDEINP
unit.
Peripheral
unit
serial
numbers
must
be
stored.
Call
an
authorized
service
centre.
E84
NFAT
The
serial
number
of
the
mass
meter
does
not
match
The
serial
number
of
the
mass
meter
differs
from
the
stored
one.
The
error
appears
after
replacing
the
mass
meter.
Peripheral
unit
serial
numbers
must
be
stored.
Call
an
authorized
service
centre.
E85
NFAT
The
serial
number
of
the
PDEDPS
pressure
sensors
unit
does
not
match.
The
serial
number
of
the
PDEDPS
unit
differs
from
the
stored
one.
The
error
appears
after
replacing
the
PDEDPS
unit.
Peripheral
unit
serial
numbers
must
be
stored.
Call
an
authorized
service
centre.
E86
NFAT
Insufficient
LPG
pressure
difference
The
pressure
difference
between
the
liquid
and
gas
phases
of
LPG
was
less
than
1
bar
for
a
period
longer
than
specified
by
the
parameter.
E86
‐
1
LPG
pressure
difference
was
less
than
1
bar
for
longer
than
specified
by
the
parameter.
E86
‐
2
An
LPG
pressure
difference
of
less
than
1
bar
was
detected
more
than
3
times
during
one
delivery.
Check
the
supply
line
pressure
and
the
gas
return
phase
line
pressure
and
the
line
permeability.
Check
the
pressure
record
in
the
LPG
directory
on
the
memory
card.
If
the
fault
persists,
call
an
authorized
service
centre.
E87
NFAT
Electromechanical
totalizer
coil
failure
The
additional
error
message
number
corresponds
to
the
totalizer
number.
It
is
necessary
to
replace
the
totalizer
coil.
Call
an
authorized
service
centre.
E88
NFAT
LPG
pressure
sensor
fault
E88
‐
1
Liquid
phase
pressure
sensor
fault
E88
‐
2
Gas
phase
pressure
sensor
fault
E88
‐
3
Fault
in
both
pressure
sensors
Check
the
connection
of
the
relevant
pressure
sensor.
Call
an
authorized
service
centre.
E89
NFAT
PDEDPS
pressure
sensors
unit
failure
The
unit
does
not
communicate
or
has
an
incorrect
checksum.
Check
the
connection
of
the
PDEDPS
unit
and
the
setting
of
its
address.
Call
an
authorized
service
centre.
E90
NFAT
Flow
in
the
auxiliary
meter
detected
during
calibration
of
the
main
meter
Check
the
auxiliary
pump
motor
disconnection
during
the
calibration
of
the
main
meter
and
the
functionality
of
the
valves
and
non
‐
return
valves
in
the
hydraulic
system.
Call
an
authorized
service
centre.
E91
NFAT
Flow
detected
in
the
main
meter
during
calibration
of
the
auxiliary
meter
Check
the
main
pump
motor
disconnection
during
calibration
of
the
auxiliary
meter
and
the
functionality
of
the
valves
and
non
‐
return
valves
in
the
hydraulic
system.
Call
an
authorized
service
centre.