background image

Installation Instructions,

Service & Warranty Information

Revised: April 2002

Models Included

•••••

 

TLP10

•••••

 

TLP15

•••••

 

TLP20

•••••

 

TLP30*

•••••

 

TLP61

NOT UL LISTED

F

IND

 

OUT

 

MORE

ON

 

THE

 

WEB

.

WILBURCURTIS.COM

WILBUR CURTIS COMPANY

 

 

  Montebello, CA 90640

DRAFT COPY

Not Released. This Version Exists as File No.

I:\DIAGRAMS\FRANK\FX-134.p65

DIGITAL AIRPOT  BREWING SYSTEM

FOR THE LATEST SPEC INFORMATION GO TO WWW.WILBURCURTIS.COM

ISO 9001 REGISTERED

C

TLP

Содержание TLP10

Страница 1: ... TLP20 TLP30 TLP61 NOT UL LISTED FIND OUT MORE ON THE WEB WILBURCURTIS COM WILBUR CURTIS COMPANY Montebello CA 90640 DRAFT COPY Not Released This Version Exists as File No I DIAGRAMS FRANK FX 134 p65 DIGITALAIRPOT BREWING SYSTEM FOR THE LATEST SPEC INFORMATION GO TO WWW WILBURCURTIS COM ISO 9001 REGISTERED C TLP ...

Страница 2: ... level in the tank rises to the correct volume the heating elements will energize automatically With ADS Systems there is no danger of element burnout caused by an empty tank 4 Turn on the control panel by pressing the ON OFF button 5 The heating tank will require 20 to 30 minutes to reach operating temperature 200 F as indicated by the READY TO BREW indicator 6 Prior to brewing dispense 12 ounces...

Страница 3: ... these steps Before changing the brew volume wait until unit reaches brew temperature Ready to Brew light comes on insert the brewcone into place on the brewer then place a measuring container centered beneath the brewcone Brew Volume Factory Pre set Full Brew to 2 2 Liters ENTER THE PROGRAMMING MODE 1 Be sure to have brewcone airpot in position Press and HOLD until hot water starts running from s...

Страница 4: ... 20 15 61 13A WC 860 VALVE LIQUID DISPENSING LEFT 220VAC 12W MODEL 30 14 WC 5231 COMPOUND SILICONE 5 OZ TUBE 15 WC 3503 LEG SCREW BUMPER 3 8 16 STUD 16 WC 102 SWITCH TOGGLE SPST 25A 250VAC RESISTIVE Models 10 20 16A WC 103 SWITCH TOGGLE DPST 25A 125 250 VAC RESISTIVE Models 15 30 61 17 WC 826 VALVE INLET 1 15 GPM 120V 10W Models 10 20 15 61 17A WC 856 VALVE INLET 1 15 GPM 240V 10W Model 30 18 WC 5...

Страница 5: ... by a professional certified technician and must comply with all local electrical mechanical and plumbing codes 3 Wilbur Curtis Company will not be responsible for the operation of equipment at other than the stated voltages on the serial plate 4 Abuse or neglect including failure to periodically clean or remove lime accumulations Manufacturer is not responsible for variation in equipment operatio...

Отзывы: