Proper system grounding is critical to reliable system operation. System grounding is
only as effective as the ground point itself. To ensure adequate protection from
interference by radio frequency energy, electrical impulse noise, and lightening or
power line surge, the building electrical ground point must comply with grounding
recommendations of the National Area Code, Article 800, and/or applicable local
building and electrical codes.
The object of ground circuit design is to establish a low resistance path to the
groundground, and to conduct a multitude of currents in such a way as to minimize
the interaction of any two or more currents. In essence, the ground connection is used
as a common conductor for many circuits: some carrying wanted signals, and others
carrying unwanted signals. The same ground that carries small networking currents
must also carry unwanted radio frequency energy, impulse noise, and lightening
surges that might otherwise interfere with system operation.
The ground connection includes an M4 threaded terminal pole that is fixed onto the
surface of the top section (by the manufacturer), a serrated washer between each
terminal connection, a flat washer, and an M4 nut.
The cage ground wire is connected to the cage in the top section, as described on
page
2-47, Connecting the Ground Wire to the Cage
.
6
Ground Wiring
Electrical Hazard. Incorrect ground wire connections to the system can cause shock,
burn, or death.
•Verify that the ground wires are 10 AWG stranded conductor.
•Verify that all ground connections of
locally supplied MDF units
are made directly
from the cage ground connection to the master ground.
•
Do not
interconnect cage ground terminals between Coral IPx cages.
•Ring terminals retain wires onto the terminal lug when the connection is loosened.
Verify that all ground wires include ring terminals at both ends.
•Verify that the ring terminals connecting to the cage and to the MDFipx are suitable for
M4 fasteners.
•Connect only a Protective Earth (PE) to the Coral IPx system.
Do not
connect a separate Telecommunications Reference Conductor (TRC).
•Resistance from the master ground or MDFipx to the building electrical ground should
never exceed 1.0 ohm. The master ground bar should be located in the switching room
as close as possible to the Coral system. Any ground connection of equipment related
to the switching Coral system should ultimately connect to the master ground.
Содержание Coral IPx 500
Страница 1: ...Coral IPx 500 Installation Procedure and Hardware Reference Manual The flexible way to communicate...
Страница 22: ......
Страница 26: ......
Страница 28: ......
Страница 42: ......
Страница 58: ...2 16 Coral IPx 500 Installation Manual Site Inspection 2 NOTES...
Страница 120: ......
Страница 126: ...3 6 Coral IPx 500 Installation Manual Power Supply Test 3 NOTES...
Страница 146: ...3 26 Coral IPx 500 Installation Manual I O Cable Installation 3 Figure 3 6 Champ Fastening to Top Section of the Cage...
Страница 149: ...Initial Power up Tests 3 29 I O Cable Installation 3 Figure 3 8 MDF Connector Configuration Left View...
Страница 152: ...3 32 Coral IPx 500 Installation Manual Installation Wrap up 3 NOTES...
Страница 154: ......
Страница 170: ......
Страница 184: ...5 14 Coral IPx 500 Installation Manual Protection Devices 5 NOTES...
Страница 188: ...5 18 Coral IPx 500 Installation Manual Power Fail PF Transfer Circuits 5 NOTES...
Страница 204: ...5 34 Coral IPx 500 Installation Manual MDFipx Units Supplied by the Manufacturer 5 NOTES...
Страница 254: ...5 84 Coral IPx 500 Installation Manual Peripheral Card with RJ 45 DA 15S Connections For Coral Interface Cards 5 NOTES...
Страница 256: ......
Страница 288: ...6 32 Coral IPx 500 Installation Manual Coral IPx 500M Main Cage Description 6 NOTES...
Страница 296: ...6 40 Coral IPx 500 Installation Manual Coral IPx 500X Expansion Cage Description 6 NOTES...
Страница 316: ......
Страница 332: ...7 16 Coral IPx 500 Installation Manual PS500 DC Power Supply Unit 7 NOTES...
Страница 350: ...7 34 Coral IPx 500 Installation Manual PS500 AC Power Supply Unit 7 NOTES...
Страница 376: ......
Страница 380: ...8 4 Coral IPx 500 Installation Manual Control Cards 8 NOTES...
Страница 404: ...8 28 Coral IPx 500 Installation Manual IMC8 Card Flash Erasable Software Memory Unit 8 NOTES...
Страница 412: ...8 36 Coral IPx 500 Installation Manual DBX Card Database Expansion Memory Unit 8 NOTES...
Страница 422: ...8 46 Coral IPx 500 Installation Manual CLA Card CoraLINK Adapter 8 Figure 8 15 CLA with RJ 45 Connection...
Страница 426: ...8 50 Coral IPx 500 Installation Manual CLA Card CoraLINK Adapter 8 NOTES...
Страница 428: ......
Страница 432: ...9 4 Coral IPx 500 Installation Manual Shared Service Circuitry Installation 9 NOTES...
Страница 452: ...9 24 Coral IPx 500 Installation Manual IPx 500M Backplane Main Service Board inside the IPx 500M Cage 9 NOTES...
Страница 460: ...9 32 Coral IPx 500 Installation Manual Three Way Conference Conference Circuitry 9 NOTES...
Страница 490: ...9 62 Coral IPx 500 Installation Manual KB1 KB2 KB3 RS 232E Data Serial Port 9 NOTES...
Страница 498: ...9 70 Coral IPx 500 Installation Manual Music Background and Music On Hold M1 M2 9 NOTES...
Страница 518: ...9 90 Coral IPx 500 Installation Manual Relay Contacts RLY1 RLY2 RLY3 9 NOTES...
Страница 520: ......
Страница 526: ...10 6 Coral IPx 500 Installation Manual Peripheral Card Installation 10 NOTES...
Страница 534: ...10 14 Coral IPx 500 Installation Manual Peripheral Card Description XXXipx and XXXsl Cards 10 NOTES...
Страница 543: ......