SINGLE /TWO STAGE OPERATING LIMITATIONS
10
15
20
25
30
35
40
45
50
55
60
65
70
-15
-10
-5
0
5
10
15
20
-20
-25
25
Outdoor temperature (°C)
Leaving water temperature setpoint (°C)
Two stage – min. entering water T.
Two stage – max. leaving water T.
Single stage – max. leaving water T.
TWO
STAGE
SINGLE
STAGE
8 Aqu@Scop HT V2
Aqu@ Scop HT
appliances are equipped with a 2-stage output system with a ratio of 1:2.
When heating needs are low and when the required outlet water temperature is below 55° C, only the
first stage is used at reduced capacity until the temperature balance point is reached. In other cases, the
Aqu@ Scop HT
operates at full capacity to supply heating needs until the chosen balance point is reached.
The outlet water temperature is automatically adjusted to the water rule (heating curve) up to a maximum
temperature of 65° C.
9.4. OPERATING LIMITS