Installer Programs
The Installer programs are typically PBX dependent parameters that must
be programmed properly in the unit for it to work properly.
In this model of the ATT 2000 all the available programs have been divided
into USER PROGRAMS and INSTALLER PROGRAMS.
The Installer Programs consist of all the PBX specific parameters which are
programmed at the time of the installation and need not be known to the
end user. These parameters may be saved separately by the Installer in the
NVRAM and may be reloaded whenever desired. The User programs are
mostly site-specific parameters which the user may need to change
whenever desired.
Extension Length:
This model of the ATT 2000 may be programmed and used in an
installation where the extension numbers are of fixed lengths or different
lengths from 2 to 5 digits. Hence, if 23, 456, 7890 and 34567 are all valid
extension numbers in a particular installation, the ATT 2000 transfers calls
to these extensions without any problem.
The minimum length of an Extension is 2 digits and maximum is 5 digits.
Hence, whenever the unit is waiting for an Extension number to be input
by the caller whether in the Main Greeting or under programming the
unit processes the digits as soon as 5 digits are received or if less than 5
digits are received, the input is processed as soon as the “Conflict timer”
duration has elapsed after the last digit was entered.
Because of this, in installations where the extensions are of 2 or 3 or 4 digits
only, the callers may notice a short delay of about 2 seconds after entering
the last digit, before the unit transfers the call. If all the extensions are of a
fixed length, this delay can be avoided by programming the Extension
Length accordingly in Program 521.
All 5xx programs are for programming a new value and 6xx programs are
for listening to the programmed value.
Program # 501:
Hook-flash timing
The hook flash duration is programmable in steps of 50 msec (0.05 sec)
from 0 to 2.45 seconds. If the Hook Flash duration is too short, the caller
hears the digits being dialed by the PBX when the call is to be transferred
to the extension. If the Hook Flash duration is too long, the call is
disconnected
Enter 501 nn.
Range for `nn' = 0 to 49
39