48
TimeProvider 500 2.0 User’s Guide
098-00172-000 Revision A – December, 2009
Chapter 2 Installation & Configuration
Configuration Setup
TP-500> show output
Output 1 type : 2.048 MHz Clock
Output 2 type : 1PPS
Output 3 type : 2.048 MHz Clock
Output 4 type : 2.048 MHz Clock
HDB3 : Enabled
Freerun output mode : on
Holdover output mode: on
1PPS offset : 2984 ns
1PPS pulse width : 100000000 ns
1PPS mode
: standard
Set the signal type for
OUT1
,
OUT2
,
OUT3
, or
OUT4
using the
set
output
command. The
<selection>
choices are shown in
.
For example, set OUT2 to
e1_ccs
with the following command:
TP-500> set output OUT2 e1_ccs
Table 2-3. Output Signal Selections for OUT1, OUT2, OUT3 and OUT4
Selection
Output Generated
Disable
No output
clk_2048
2.048MHz square wave
(default for OUT1, OUT2, OUT4)
e1_ccs
E1 CCS, no CRC4
e1_ccs4
E1 CCS, with CRC4
e1_cas
E1 CAS, no CRC4
e1_cas4
E1 CAS, with CRC4
e1_ais
E1 AIS
clk_1544
1.544 MHz square wave
t1_sf
Super-Frame T1
t1_esf
Extended Super-Frame T1
t1_iso_pulse
T1 Isolated Pulse
1 PPS
Pulse Per Second (default for OUT2)
Содержание TimeProvider 500
Страница 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 122: ...122 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 Chapter 4 CLI Commands Show Commands ...
Страница 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Страница 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...