098-00172-000 Revision A – December, 2009
TimeProvider 500 2.0 User’s Guide
99
Chapter 4 CLI Commands
Set Alarm Commands
Figure 4-2.
Alarm Configuration Commands
set alarm-config delay
The number of alarms has increased from 14 to 19 in version 2.0.
This command allows the user to delay the reporting of selected alarms (in
seconds). The
alarm_num
option allows you to select an individual alarm.
Syntax:
set alarm-config delay { alarm
alarm_num
} duration
delay_time
Example:
Sets alarm number 5 delay time to 10 seconds
set alarm-config delay alarm 5 duration 10
Response:
Alarm 5 delay set to 10 seconds
set alarm-config level
The number of alarms has increased from 14 to 19 in version 2.0
.
This command configures the severity level of the selected alarm. The
alarm_num
option
allows you to select an individual alarm. See
for
more information. The selected severity may change the alarm LED indication (see
, on page 126 for details).
Syntax:
set alarm-config level { alarm
alarm_num
} { event | minor | major | critical }
Range:
alarm_num
= [0, 1, … , N], N currently= 19
Default:
See
for default severities.
Example:
Sets all alarms to minor severity.
set alarm-config level alarm 9 minor
alarm-config commands
alarm_num
level
alarm_num
enable
disable
state
alarm_num
duration
<delay time>
delay
minor
major
critical event
alarm_num
enable
disable
proxy
Содержание TimeProvider 500
Страница 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 122: ...122 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 Chapter 4 CLI Commands Show Commands ...
Страница 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Страница 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...