Chapter 4 CLI Commands
Set Commands
This command enables the user to select either UTC or local time settings for CLI
commands that show the current time such as the
commands.
Syntax:
TP-500> set clock timescale[local | tai | utc]
Range:
local - Timescale set to local
tai - Timescale set to TAI
utc - Timescale set to UTC
Default:
set clock timescale = utc
Example:
set clock timescale utc
Response:
Timescale changed to UTC
set clock timezone
This command in new for version 2.0.
This command enables the user to set the timezone offset in hours and minutes for
reporting of time in logs and CLI command that show the current time such as the
commands.
Syntax:
TP-500> set clock timezone
<tim/-HH:MM>
Example:
set clock timezone -01:00
Response:
Setting timezone offset to: +01:00
Note
: Setting the timescale does not affect timestamping in logs. The
timestamping in logs always uses UTC.