162
TimeProvider 500 2.0 User’s Guide
098-00172-000 Revision A – December, 2009
Version 1.0 Factory Defaults
2.048 MHz Outputs
Holdover
< 20 microseconds after 24 hours following loss of PTP reference.
Test Conditions:
TimeProvider 500 subjected to 5
C temperature variation throughout test.
TimeProvider 500 referenced to PTP for at least 24 hours prior to the start of holdover.
TimeProvider 500 powered > 5 days prior to the test.
Version 1.0 Factory Defaults
provides general and communication default values.
Table C-11. 2.048 MHz Specifications
Parameter
Specification
Amplitude
1.0 to 1.9 volts peak, 1.5 volts peak nominal into 120
0.8 to 1.5 volts peak, 1.2 volts peak nominal into 75
Wave Shape
Square Wave
Termination Impedance
75
Table C-12. General and Communication Parameters
Description
Default Value
Value Range
Acc-Grandmaster IP Address
0.0.0.0
Valid IPv4 Address
Alarm Delay
3 seconds
{ Alarm Alarm_Num | All } {Enable | Disable }
Alarm State
Enabled
Enable | Disable
Announce Interval
1 second
1, 2, 4, 8 second(s)
Bridge Time
180 seconds
[0, 1, ..., 86400]
Domain 0
0-127
DSCP
0
0-63
EIA-232 Port
57.6k-8-N-1
Fixed
Firewall
Allowed for
telnet / ICMP
Allowed | Blocked
Freerun Output
ON
{ ais | on | squelch }
Содержание TimeProvider 500
Страница 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 122: ...122 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 Chapter 4 CLI Commands Show Commands ...
Страница 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Страница 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...