![Symmetricom TimeProvider 500 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/symmetricom/timeprovider-500/timeprovider-500_user-manual_1419600028.webp)
28
TimeProvider 500 2.0 User’s Guide
098-00172-000 Revision A – December, 2009
Chapter 1 Overview
Functional Description
The frame format and disable controls are coupled between outputs 1 and 4 and
between outputs 2 and 3. For non-1PPS signals, these output pairs must have the
same signal type since they share the same framer. Only outputs 1 and 2 can be
configured for the 1PPS signal.
If output 4 is disabled, then output 1 will be disabled if it is not configured for 1PPS.
Outputs 3 and 2 have a similar coupling.
For example, if output 1 is configured for 1PPS, then output 4 can be configured for
any signal type, except 1PPS. If output 1 is configured for E1, then output 4 must be
configured as an E1 with the same frame format.
show the supported combinations of output settings.
Table 1-1. Output 1 and Output 4 Configurations
Output 4
Output 1
T1
E1
1.544 MHz
2.048 MHz
Disabled
1PPS
Supported
Supported
Supported
Supported
Supported
T1
Supported
E1
Supported
1.544 MHz
Supported
2.048 MHz
Supported
Disabled
Supported
Supported
Supported
Supported
Supported
Содержание TimeProvider 500
Страница 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Страница 122: ...122 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 Chapter 4 CLI Commands Show Commands ...
Страница 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Страница 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...