![Symmetricom TimeProvider 500 series Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/symmetricom/timeprovider-500-series/timeprovider-500-series_reference-manual_1419598051.webp)
Issue 2: Sep 99
TMSL 097-44018-26
Page 51
COMMAND CODE: ED-USER-SECU
PURPOSE
EDIT USER SECURITY
This command changes a user’s name, password, and access level. The user name and password are case
(uppercase/lowercase) sensitive and must be entered exactly as assigned. One user is assigned at the fac-
tory, and up to 16 additional users can be assigned (for a total of 17 users).
INPUT FORMAT
ED-USER-SECU:[<tid>]:<uid>:<ctag>::<new uid>,<new pid>,,<uap>;
EXAMPLE
Input:
ED-USER-SECU::BIG:155::LITTLE,SIZE,,3;
Response:
SANJOSE-114 1997-12-08 15:04:13
M
155 COMPLD
;
This example, tagged as command 155, changes the user’s name from BIG to LITTLE, changes the pass-
word to SIZE, and changes the access level to 3.
parameter
value
meaning
uid
user name
the user whose name, password, and access level is being
changed
new uid
up to 10 alpha-numeric characters
new user name
new pid
up to 10 characters (see note be-
low)
new password
uap
1–5
user access level (5 is highest level)
Note: The password can have a minimum of 1 character and a maximum of 10 characters. At least one alpha
character must be used. Alpha characters can be uppercase, lowercase, or a mixture of both. Any printable char-
acter can be used except: comma (,), colon (:), semicolon (;), null (), space ( ), ampersand (&), and equal sign (=).