![Symmetricom TimeProvider 500 series Скачать руководство пользователя страница 144](http://html.mh-extra.com/html/symmetricom/timeprovider-500-series/timeprovider-500-series_reference-manual_1419598144.webp)
TMSL 097-44018-26
Issue 2: Sep 99
Page 144
COMMAND CODE: SET-SID
PURPOSE
SET SOURCE IDENTIFIER
This command changes the system identification, or source identifier. The <tid> in an input command is
the <sid> of the target system. The <sid> is included in every response sent by the system. The <sid> can
be up to 20 characters beginning with a letter, and is limited to letters, numerals and hyphens. The <sid>
is case sensitive.
Note:
The sid is recommended to be the target’s CLLI code, if available (alternatively, the office name
can be used).
INPUT FORMAT
SET-SID:[<tid>]::<ctag>::<sid>;
Caution:
The letter/number combinations “NO”, “E1”, “E2”, and “E3” cannot be entered
alone
in any field in this command. These combinations can be used if additional characters are en-
tered before or after these combinations.
EXAMPLE
Input:
SET-SID:::119::SANJOSE-114;
Response:
SANJOSE-114 1997-12-08 15:04:13
M
119 COMPLD
;
This example, tagged as command 119, sets the sid as SANJOSE-114.