TMSL 097-44018-26
Issue 2: Sep 99
Page 34
COMMAND CODE: ED-EQPT (Contd)
INPUT FORMAT (Contd)
aid
parameter
value
meaning
GTI-a
framing
CAS
channel associated signaling
CAS4
channel associated signaling with cyclic redundancy check 4
CRC4
common channel signaling with cyclic redundancy check 4
D4
D4 framing
ESF
ESF framing
FAS
common channel signaling
troublecode
ALW
AIS is sent on all outputs when card has major alarm
INH
all outputs are squelched when card has major alarm
portseverity
(null)
(not applicable)
osc1
QTZ
oscillator 1 (OSC A) is quartz clock
RB
oscillator 1 (OSC A) is rubidium clock
osc2
QTZ
oscillator 2 (OSC B) is quartz clock
RB
oscillator 2 (OSC B) is rubidium clock
integration
1
2
3
4
clklevel
(null)
(not applicable)
alarmlead
signaltype
ANALOG
output signal is analog
DIGITAL
output signal is digital
MCA
framing
(null)
(not applicable)
troublecode
portseverity
MJ
a port failure causes a major alarm
MN
a port failure causes a minor alarm
osc1
(null)
(not applicable)
osc2
integration
clklevel
alarmlead
ALW
a protection switch activates the shelf alarm lead
INH
a protection switch does not activate the shelf alarm lead
signaltype
(null)
(not applicable)