COMMAND CODE: RTRV-SSM-PORT (Contd)
RESPONSE FORMAT (Contd)
parameter
value
meaning
ssmmsg
QL-DNU
Do not use for synchronization
QL-DUS
Do not use for synchronization
QL-NORM
No quality level has been assigned; the incoming quality level
message will be used, along with equipment conditions, to de-
termine the output quality level message
QL-PRC
Signal is traceable to a primary reference clock
QL-PRS
Signal is traceable to a primary reference source
QL-RES
Signal traceable to a user-defined level
QL-SEC
Signal is traceable to SDH equipment clock
QL-SMC
Signal is traceable to SONET minimum clock
QL-SSUL
Signal is traceable to synchronization supply unit local
QL-SSUT
Signal is traceable to synchronization supply unit transit
QL-ST2
Signal is traceable to a stratum 2 level
QL-ST3
Signal is traceable to a stratum 3 level
QL-ST3E
Signal is traceable to a stratum 3E level
QL-ST4
Signal is traceable to a stratum 4 level
QL-STU
Signal is traceable to an unknown stratum level
QL-TNC
Signal is traceable to a transit node clock
QL-UNK
Signal is traceable to an unknown stratum level
ssmsa4
ALW
Allows the Sa4 bit to be used for SSM messages
INH
Inhibits the Sa4 bit from being used for SSM messages
ssmsa5
ALW
Allows the Sa5 bit to be used for SSM messages
INH
Inhibits the Sa5 bit from being used for SSM messages
ssmsa6
ALW
Allows the Sa6 bit to be used for SSM messages
INH
Inhibits the Sa6 bit from being used for SSM messages
ssmsa7
ALW
Allows the Sa7 bit to be used for SSM messages
INH
Inhibits the Sa7 bit from being used for SSM messages
ssmsa8
ALW
Allows the Sa8 bit to be used for SSM messages
INH
Inhibits the Sa8 bit from being used for SSM messages