Issue 2: Sep 99
TMSL 097-44018-26
Page 137
COMMAND CODE: SET-ATTR-CONT (Contd)
PURPOSE (Contd)
5.
1-for-N output protection (all TO cards except TO-EA5, EA-10, EA-10M, EA-20, & EA-20M) (aid =
MCA):
a. Automatic/manual switching:
•
Automatic (AUTO): if a fault occurs in a timing output card, the outputs are automatically
switched to the same timing output card type in an HS slot (OPR-PROTNSW command
does not function)
•
Manual (MAN): if a fault occurs in a timing output card, the outputs are not switched to
the same timing output card type in an HS slot (the outputs must be manually switched
via the OPR-PROTNSW command)
b. Revertive/nonrevertive switching:
•
Revertive (RVRT): the protection switch will switch back to the original TO card when the
fault clears (requires <protmode>=AUTO)
•
Nonrevertive (NRVRT): the protection switch will not switch back to the original TO card
when the fault clears
INPUT FORMAT
SET-ATTR-CONT:[<tid>]:<aid>:<ctag>::<conttype>[,<protmode>,
<p1>,<p2>,<p3>,<p4>,<p5>,<p6>,<p7>,<p8>,<p9>,<p10>];
The parameter values in the table below are as follows:
a
= 1–2
b
= 1–12
aid
parameter
value
meaning
DCIM-ALL
conttype
NO
each DCIM card is stand-alone
1+1
the DCIM cards operate in a combined mode as 1 card with 4 inputs
protmode
(null)
(not applicable)
p1–p10
GTI-a
conttype
OFF
SSM not supported
SSME
SSM supported for GTI-18 cards
SSMEC
same as SSME plus one additional quality level: QL-UNK
SSMT
SSM supported for GTI-17 cards
protmode
(null)
(not applicable)
p1–p10