![Symmetricom TimeProvider 500 series Скачать руководство пользователя страница 110](http://html.mh-extra.com/html/symmetricom/timeprovider-500-series/timeprovider-500-series_reference-manual_1419598110.webp)
TMSL 097-44018-26
Issue 2: Sep 99
Page 110
COMMAND CODE: RTRV-MSG-EQPT (Contd)
RESPONSE FORMAT (Contd)
EXAMPLE
Input:
RTRV-MSG-EQPT::DCIM-ALL:155;
Response:
SANJOSE-114 1997-12-08 15:04:13
M
155 COMPLD
"DCIM-1:QL-PRS"
"DCIM-2:QL-PRS"
;
This example, tagged as command 155, shows the output of DCIM cards 1 and 2 to be QL-PRS.
ssm-state
meaning
QL-ALW
Output of card is AIS
QL-DNU
Do not use for synchronization
QL-DUS
Do not use for synchronization
QL-IDLE
SSM is not used (idle code is sent)
QL-INH
No output message
QL-PRC
Signal is traceable to a primary reference clock
QL-PRS
Signal is traceable to a primary reference source
QL-RES
Signal is traceable to a user-defined level
QL-SEC
Signal is traceable to SDH equipment clock
QL-SMC
Signal is traceable to SONET minimum clock
QL-SSUL
Signal is traceable to synchronization supply unit local
QL-SSUT
Signal is traceable to synchronization supply unit transit
QL-ST2
Signal is traceable to stratum 2 level
QL-ST3
Signal is traceable to stratum 3 level
QL-ST3E
Signal is traceable to stratum 3E level
QL-ST4
Signal is traceable to stratum 4 level
QL-STU
Signal is traceable to unknown stratum level
QL-TNC
Signal is traceable to transit node clock
QL-UNK
Signal is traceable to unknown stratum level