TMSL 097-44018-26
Issue 2: Sep 99
Page 30
COMMAND CODE: ED-COM (Contd)
INPUT FORMAT (Contd)
parameter
value
meaning
comtype
X25
for use with X.25 PAD (sets configuration for Black Box Corporation’s X.25 PAD-8
only with the following settings:
a. drops call if idle time is greater than 1 minute
b. fixed destination id
Note: If the <comtype> is set to X25 and TimeScan NMS or TMN is used, refer to the
PAD manual and the X.3 Standard to set the following parameters in the PAD Profile:
disable ECHO, enable MESSAGES, and disable SERVICE SIGNALS.
MODEM
for use with modem with autodial (sets RS232 control leads to communicate with any
Hayes-compatible modem that has autodial)
TERM1
for use with dumb terminal (VT100 with no DSR/DTR support and message buffering
disabled) (the autologoff feature will not function on a port with a comtype of TERM1)
TERM2
for use with dumb terminal (VT100 with DSR/DTR support and message buffering
enabled) or modem without autodial
REMOTE
allows communication with a remote shelf via the specified communication port
endoftext
00–9F
this hexadecimal number specifies 1 character as an additional end-of-text identifier;
this character does not replace the TL1 end-of-text terminator (;); a 00 indicates that
there is no end-of-text identifier (refer to an ASCII table for the hexadecimal code for
a particular character)
echo
ALW
allows local echo
INH
inhibits local echo
compri
INH
communication through a port with this designation is inhibited (INH is not allowed on
COM2)
ALW0
allows normal communication; autonomous messages are not sent out a port with
this priority level
ALW1
allows normal communication; autonomous messages are always sent out this port
regardless of the priorities of the other ports (this is the highest port priority)
ALW2
allows normal communication; autonomous messages are sent out this port only if
there are no ports with a priority level of ALW1 (this is the second-highest port
priority)
ALW3
allows normal communication; autonomous messages are sent out this port only if
there are no ports with a priority level of ALW1 or ALW2 (this is the lowest port
priority)
hwcontrol
ALW
allows external equipment to stop the DCD system from sending messages by
setting the clear to send (CTS) lead low, or continue messages by setting the CTS
lead high
INH
inhibits external equipment from controlling DCD system messages by manipulation
of the clear to send (CTS) lead