TimeAnalyzer 7x00 User’s Guide
098-00208-000 Revision A – February, 2010
Chapter 3 Configuring
TimeWatch Probe Module Configuration
Connect Via Ethernet
It is also possible to use a telnet or SSH connection to configure the Probe. A
crossover Ethernet cable or Ethernet hub with no network connection is required to
connect a PC to the Ethernet port if it is not on an existing network.
Using a telnet/SSH client (not Windows telnet), connect to the probe. After
connection a login screen will show. Enter the username swconf and when
prompted enter the password fr7ebi. This will enter a menu-driven configuration
interface as described in the following section.
Configure the Management PC
The factory default address of the probe is 192.168.1.10. It will be necessary to
change the IP address of the PC configuring the probe. Under Windows this can be
achieved by opening Network and Dial-up Connections from Control Panel,
right-clicking on Local Area Connection, selecting Properties, selecting Internet
Protocol, and selecting Properties. Set the IP address to 192.168.1.2 and subnet
mask to 255.255.255.0. If the IP address of the probe has been previously changed
then the new IP address needs to be entered via telnet or SSH; the PC must be
connected to the same network. If the IP address of the probe is not known this can
be changed or retrieved as detailed in
above.
Configuring the TimeWatch Probe Module
This section describes the TimeWatch probe module menus. Only the General and
Ethernet menus are needed to configure TImeWatch with the TimeAnalyzer 7500.
Other menus may be described but can be ignored. See the TimeWatch Operation
and Service Guide for additional details.
Use the
General
menu to configureTimewatch to operate with TimeMonitor, and
to select the port to be used for communication with TimeMonitor.
Notes:
The Windows "telnet" program will not correctly connect to the
probe, so an alternative application is required. Symmetricom
recommends 'Putty', which is available on the TimeAnalyzerr 7500
support CD. It is also available at:
http://www.chiark.greenend.org.uk/~sgtatham/putty/
Notes:
The Default IP address for the TimeWatch module is:
IP Address
192.168.1.10
Notes:
To avoid connectivity problems, remember to reset the IP
address of the PC before attempting to connect to other networks.