098-00208-000 Revision A – February, 2010
TimeAnalyzer 7x00 User’s Guide
71
Chapter 3 Configuring
Probe-Related Commands
set ptp-probe
Use this command with a TP5000 that is configured in Probe mode to specify the
Grandmaster IP address and Clock ID. This command is used to set the interval
rate for Sync and Delay Requests and the lease duration for the specified Probe
IOC card and port. This command is also used to restart the specified Probe IOC
card and port.
Command Syntax:
To set the IP address and Clock ID for the Grandmaster being tested by the
Probe:
set ptp-probe ioc1-[y] active-probe gm-clock-id <clock-id>
gm-ip <addr> [vlan-id <vlan>]
where
y = 1|2, the port number on the IOC
<clock-id> is in the form “xx:xx:xx:xx:xx:xx:xx:xx”
To set the interval rate for Sync and Delay Requests from the Probe:
set ptp-probe ioc1-y active-probe interval <int-value>
where
The interval is 2
z
seconds, where z is <int-value>.
To set the maximum lease duration for the Probe:
set ptp-probe ioc1-[y] active-probe duration <dur-value>
To restart the specified Ethernet port on the Probe:
set ptp-probe ioc1-[y] restart
Ranges:
Interval = 0.015625 to 128 seconds (int-value = -6 to 7)
Duration = 10 to 1000 seconds
Defaults:
Interval = 1 second (int-value = 0)
Duration = 300 seconds
Note:
The Time Analyzer option must be purchased to enable the
functionality of all “ptp-probe” commands.