098-00208-000 Revision A – February, 2010
TimeAnalyzer 7x00 User’s Guide
61
Chapter 3 Configuring
Configuring TP5000 Module Using TimeMonitor PDV
TimeMonitor PDV can be used to set the IP address for the MGMT port on IMC card
in the TP5000 probe module, but CLI commands for the TP5000 module must be
entered manually.
Status info for the IMC card shows the current IP address being used for the MGMT
port. Use the following command to display the status for the IMC card in the
TP5000 probe module.
show ip status imc
Use the following command to change the IP address for the MGMT port:
set ip imc address <IP-address> netmask <mask_value>
gateway <gateway_value>
In order for the configuration change to take effect, the interface must be restarted
with the following command:
set ip imc restart
Procedure
Setting IP Address for MGMT Port
The following procedure shows how to set the IP address for the MGMT port on the
TP5000 probe module to a sample value of 192.168.106.16, with a gateway of
192.168.106.255, and a mask of 255.255.255.0. (If no gateway, use value of
0.0.0.0).
1. If using the TimeMonitor PDV software, select the radio button for the Command
mode.
The “Login:” prompt will appear in the main display
If entering commands directly to the TP5000 probe module via telnet with a
terminal emulator using the serial port, the “Login:” prompt will appear after the
terminal emulator opens.
2. Enter the Username for the TP5000 probe module at the prompt in the main
display. Click the
Enter
button on user’s computer.
3. Enter the Password for the TP5000 probe module at the prompt in the main
display. Click the
Enter
button on the user’s computer. The TP5000 probe
module prompt will appear.