![Symmetricom TimeAnalyzer 7500 Скачать руководство пользователя страница 141](http://html.mh-extra.com/html/symmetricom/timeanalyzer-7500/timeanalyzer-7500_user-manual_1419617141.webp)
098-00208-000 Revision A – February, 2010
TimeAnalyzer 7x00 User’s Guide 139
Appendix A Specifications and Factory Defaults
TP5000 Probe Module Specifications & Factory Defaults
Table A-15. TP5000 Probe Module Telecom Output Port Parameters
Description
Default Value
Value Range
Telecom Output Port State
Enable
Enable | Disable
Telecom Output Port Frame
Type
freq2048khz
CCS | CAS | freq2048khz
Telecom Output Port CRC
Disable
Enable | Disable
Telecom Output Port SSM
Disable
Enable | Disable
Telecom Output Port SSM Bit
8
4 | 5 | 6 | 7 | 8
Telecom Output Generation
Normal
Warm-Up | Free run |
Fast-Lock | Normal
Table A-16. TP5000 Probe Module Telecom Input / Output Parameters
Description
Default Value
Value Range
Telecom IO Port 1
Input
Input | Output
Telecom IO Port 2
Input
Input | Output
Table A-17. PTP Probe Port IP Parameters
Description
Default Value
Value Range
IOC1-y IP Address
IOC
1-1
IOC
1-2
192.168.1.11
192.168.2.11
Valid IPv4 Address
IOC1-y IP Mask
255.255.255.0
Valid IPv4 Mask
IOC1-y IP Gateway
0.0.0.0
Valid IPv4 Address
IOC1 Port Redundancy
(Bonding)
Disable
Enable | Disable
IOC IP State
Enable
Enable | Disable