Chapter 2 Setting Up
Connecting LAN and RS-232
Connecting LAN and RS-232
The modules in the TimeAnalyzer 7x00 each have a LAN connection and RS-232
connection.
TimeAnalyzer 7x00 Communications Connections
The IMC card allows user control of the TP5000 probe module in the TimeAnalyzer
7x00. The EIA-232 serial port (labeled CRAFT) and Ethernet Management port
(labeled “MGMT”) are located on its IMC card, as shown in
.
For the TP500 client module, the EIA-232 serial port is located on its front panel, as
shown in
. The RJ-45 connector labeled “1588” is used for remote
management in addition to being the connection into the network that is providing
the grandmaster clock(s).
For the TimeWatch probe manual, the Ethernet Management port (labeled “LAN”) is
located on its front panel. The EIA-232 serial port is located on the Power
Distribution Panel.
LAN Ports
The LAN ports are standard 10/100Base-T shielded RJ-45 receptacles. To connect
a TimeAnalyzer 7x00 module to an Ethernet network, use a twisted pair Ethernet
RJ-45 cable.
The connector pinouts for all LAN ports in the TimeAnalyzer are listed in
.
Note:
TimeAnalyzer’s internal 5-port switch does not support VLAN.
Symmetricom recommends that the internal switch only be used for
management connections. See
.
Table 2-4. LAN Ethernet Connector Pin Assignments
Signal Name
Pin
TX+ (Transmit positive)
1
TX- (Transmit negative)
2
RX- (Receive negative)
3
RX+ (Receive positive)
6
Not Used
4, 5, 7, 8