TimeAnalyzer 7x00 User’s Guide
098-00208-000 Revision A – February, 2010
Chapter 3 Configuring
Provisioning the TP500 PTP Client Module
TP500> set ptp address gm1 192.168.5.52
8. Confirm network communication between the TP500 module and Grandmaster
with the ping command.
Use an Ethernet cable to connect the TP500 module 1588 port to an Ethernet
switch that is connected to the same network as the Grandmaster. The small
green LED on upper-right corner of "1588" connector should be lit.
Example:
TP500> ping 192.168.1.11 <enter>
Pinging 192.168.1.11 [192.168.1.11]:
Reply from 192.168.1.11: time=0ms
Reply from 192.168.1.11: time=0ms
Reply from 192.168.1.11: time=0ms
Reply from 192.168.1.11: time=0ms
Notes:
The default interface for gm1 in non-VLAN connection is if0,
so the command to assign gm1 to interface if0 is not shown.
If the TA7x000 was used previously with a VLAN connection,attach
the Grandmaster to the non-VLAN interace, if0, with the command
set interface attachments {GM1 | GM2 | NODE-MGR}
{if0 | if1| if2 | if3 | if4}
.
See the TP500 User’s Guide for additional details about configuring
VLAN and interface attachments.
Example:
TP500>set interface attachments gm1 if0