60
TimeAnalyzer 7x00 User’s Guide
098-00208-000 Revision A – February, 2010
Chapter 3 Configuring
Configuring TP5000 Module Using TimeMonitor PDV
Figure 3-3.
Set IP Command Hierarchy - TP5000 Probe Module
Configuring the Ethernet Port
DHCP Mode
Use the following procedure to configure the TP5000 probe module to enable
DHCP on the MGMT port.
1. Login at the Admin or Config-user level (see
2. Type
ip-mode imc dhcp
and press
Enter
.
3. Type
set ip imc restart
and press
Enter
.
Connecting Through an Ethernet LAN
1. Ensure that the TP5000 probe module is connected to a LAN.
2. Telnet from your computer to the IP address assigned to the TP5000 probe
module.
3. Type your user name and press
Enter
. If you are not assigned as a user in the
system, contact the system administrator or see
4. Type your assigned password and press
Enter
. The system prompt appears.
Note:
The telnet firewall is set to Block by default. Use the following
command to set the IMC firewall to Allow for telnet communications:
set firewall imc telnet allow