E1 Measurements
3. Start the TimeMonitor Watch module on the PC used to communicate with the
TimeWatch probe module.
4. Click the
TCP/IP
button.
5. Enter the IP address for the external client to be measured. Click the
OK
button
to return to the main screen.
6. Use the
TimeMonitor Watch
radial button for "Ref" to select E1 or 2M as the
signal format of the Reference input. Select 2M if using the TP5000 probe
module in its default mode for Port 1 output.
7. Use the
TimeMonitor Watch
radial button for "Meas" to select E1 or 2M as the
signal format from the external client
8. Use the
Sample Rate
radial buttons to select the desired sample rate for the E1
measurement.
9. To begin the measurement, click the
Start
button.
10.
During a measurement, a plot of the phase collected so far can be produced by clicking
the
View
button, as shown in
11.
By clicking the MTIE button, Live MTIE can be viewed, as shown in
12.
By clicking the TDEV button, Live TDEV can be viewed, as shown in
.
13.To end the measurement, click the
Stop
button.