Chapter 6
NetBackup 5220 hardware removal and replacement
103
DIMM sockets
Note: It does not matter into which sockets you place the DIMMs, they are
interchangeable.
14.
Position a DIMM above a socket.
15.
Align the notch on the bottom edge of the socket with the key in the
DIMM socket.
16.
Insert the bottom edge of the DIMM into the socket.
17.
When the DIMM is inserted, push down on the top edge of the
DIMM until the clips snap into place.
18.
Make sure the clips are firmly in place.
19.
Repeat for the other five DIMMs.
20.
Replace the plastic air duct.