112 Chapter 6
NetBackup 5220 hardware removal and replacement
Installing or replacing PCI add-in cards
19.
Be sure that riser assembly fits securely into the equivalent sockets
on the mainboard.
20.
Connect any cables to the PCI add-in cards as needed.
21.
Replace the chassis cover from the top rear of the NetBackup 5220
enclosure.
22.
Slide the cover from the rear of the device towards the front.
Carefully align both sides of the cover with the sides of the chassis itself. Do not
allow warping or damage to the cover.
23.
Reinstall the single screw at the right front of the external chassis.
24.
Reinstall the NetBackup 5220 into the rack.
25.
Connect peripheral cables and the two main AC power cables.
26.
Turn on power to the device to restart.