Chapter 6
NetBackup 5220 hardware removal and replacement
133
Fan connectors
15.
Disconnect all six fan connectors (to the mainboard).
16.
Carefully lift the fan module up and out of the chassis.
17.
Place a new fan module into the chassis.
18.
Line up the pins on the chassis floor with the matching holes on the
bottom of the fan assembly.
19.
Push down on the fan assembly to secure it into the chassis.
20.
Connect each of six fan connections to the connectors on the mainboard.
21.
Replace the fan baffle between fans 3 and 6.
22.
Resecure the bridge, clipping it into place.
23.
Replace the air baffle on the left side of the chassis.
24.
Replace the air duct.
25.
Re-install the PCI riser assembly.
26.
Replace the chassis cover , making sure to secure the screw that holds the
cover down.
27.
Replace thc NetBackup 5220 into the rack cabinet.
28.
Replace the AC main power cable and peripherals.
29.
Power up the device through the OS.