Sutron Corporation X-Link Operations & Maintenance Manual, Rev 1.63 5/24/2016 pg. 54
2.
The next line contains the event that caused the notification. It will look like
the corresponding log entry except that there will be no timestamp.
3.
The next line contains the measurement data for each active measurement
that has a valid last reading. It will include the name of the sensor, the most
recent reading, and any alarm details.
4.
At the end of the SMS are the number of transmissions made today.
Below is the boot up notification. There is no measurement data because the
system had no time to make a reading.
DEV1GPRS
Reset Upgrade,1
Tx today: good 0, bad 0
Here is an alarm notification.
DEV1GPRS
Alarm In,4
BV 14 Into Alarm
STAGE 10.157
PRECIP 0.00
TEMP 25.7
Tx today: good 1, bad 0
The number 4 after
Alarm In
means that measurement 4 was in alarm. The
reading that caused the alarm is
BV 14 Into Alarm
.
Into Alarm
means the reading
caused the station to go into alarm. See the Alarms section for details. (page 90.)