Sutron Corporation X-Link Operations & Maintenance Manual, Rev 1.63 5/24/2016 pg. 178
06/11/2013,12:42:00,STAGE,0.25,,G
06/11/2013,12:42:00,BATT,13.2,,G
06/11/2013,12:42:00,TEMP,22.2,,G
Note that if no measurements are enabled, GF commands for sensors.txt and
curdata.txt will return errors.
18.4.2.2.
Status information
If the file "status.txt" is asked for, the data returned will be similar to what
LinkComm shows on the Main Status and on Telemetry Status.
X-Link 1.30
Station Name=DEV_ONE
Recording = On
3 Meas Active
WiFi: Initializing
System Time 2013/06/12 11:36:46
Recording since 2013/06/11 12:41:06
Booted at 2013/06/12 11:36:23
Battery 13.2V
Station Name=DEV_ONE
Sent bytes: total 197, today 197
Received bytes: total 0, today 0
Msgs received: total 1, today 1
System Time 2013/06/12 11:36:46
18.4.2.3.
Sensor data
Access recent measurements and setup details by asking for the file
"sensors.txt". The data in the file will describe the measurement setup along
with the most recent radings. The data mimic's Sutron 9210's sensor view. Tab
characters are used to denote column breaks. Each line is terminated by a CR/LF.
STAGE Analog = 0.25; Q = G
BATT Battery = 13.2; Q = G
TEMP Internal Temp = 22.2; Q = G
Note that if no measurements are enabled, GF commands for sensors.txt and
curdata.txt will return errors.