4-20
M
A
ANALOG
INPUT
Range
0 - 22mA
Resolution
<1nA
Accuracy @25⁰C
0.02%
Loop Power
External
Loop Resistance
200 Ohm
TEMPERATURE
MEASUREMENT
(I
NTERNAL
)
Range
-40°C to +60°C
Accuracy
± 3 deg
DIGITAL
INPUT
1,2
-
TIPPING
BUCKET
TYPE
Switch Contact Type
Pulse Width between 30ms & 120ms
Range DC to 120 tips/min. (min)
DIGITAL
INPUT
1,2
-
FREQUENCY
TYPE
Input Range
0-5 V
Minimum Frequency
2.8 Hz
Maximum Frequency
10 kHz
DIGITAL
INPUT
1,2
-
COUNTER
TYPE
Input Range
0-5 V
Maximum Frequency without Debouncing
10 kHz
Maximum Frequency with Debouncing
300Hz