Sutron Corporation X-Link Operations & Maintenance Manual, Rev 1.63 5/24/2016 pg. 135
Setup changed
Recording = Off, Range (0=Off, 1=On)
14.10.
Machine-to-Machine Communication
All commands may be preceded with an !. If they are, there is no echo, and a
concise reply meant for machine-to-machine interaction is returned.
Commands would be preceded by an ! if they were sent by an Xpert or some
such computer. For example, instead of typing SETUP, you may type !SETUP.
When command are preceded with an !, no help text is given, no range is shown
for measurement, no confirmation of commands is shown, and no key stroke is
expected between scrolling pages.
14.11.
Auto Output
When X-Link has
auto output
mode enabled, it will automatically send data out
on the USB port. (For more details, see page 98.)
14.12.
Command Reference
Documentation Legend:
0
If a 0 follows
a listed command, it means that the command can optionally
be followed by the character 0. E.g. DIAG will show the system diagnostic
status. DIAG 0 will first show current status and then clear the status.
All commands may be preceded with an !. If they are, a concise reply meant for
machine to machine interaction is returned. Commands would be preceded by
an ! if they were sent by an Xpert or some such computer.
E.g. MEAS will show
M1 BARO
6.41
2007/12/12 14:55:22
!MEAS will show
6.41, 2007/12/12 14:55:22
Every setup variable can be viewed by typing its name.
E.g. STATION NAME will show the current name.
Every setup variable can be changed by typing its name = new value.
E.g. STATION NAME = STURON will set the current name to SUTRON.
For a list of all the setup names, see the Setup section.