Charge regulator is not
connected correctly
Check connection
referring to the wiring
diagram
Connect the charge regulator
correctly
Charge regulator
defective
For troubleshooting see
respective manual
Repair by authorized service station
11.5
Checking the open circuit voltage
A simple test to detect an internal defect of the generator is measuring the open circuit
voltage. Disconnect the cables from the generator and connect a voltmeter to the positive
and negative line. To avoid injury, dismantle the rotor blades beforehand. Now turn the
hub by hand. Count the revolutions within a certain period (e.g. 30 revs within 10 seconds
= 180 rpm). Watch the voltage. The voltage and the speed should correspond to the
following diagram: