Motherboard Installation
This section explains the first step of physically mounting the X5DPA-TGM+ into
the SC811T-350 chassis. Following the steps in the order given will eliminate the
most common problems encountered in such an installation. To remove the
motherboard, follow the procedure in reverse order.
1.
Accessing the inside of the 6013A-T (see Figure 2-5)
Two release buttons are located on the top cover of the chassis.
Depressing both of these buttons while pushing the cover away from
you until it stops. You can then lift the top cover from the chassis to
gain full access to the inside of the server. (If already installed in a
rack, you must first release the retention screws that secure the unit
to the rack. Then grasp the two handles on either side and pull the unit
straight out until the rails lock into place.)
2.
Check compatibility of motherboard ports and I/O shield:
The X5DPA-TGM+ requires a chassis big enough to support a 12" x 10"
motherboard, such as Supermicro's SC811T-350 1U rackmount. Make
sure that the I/O ports on the motherboard align properly with their
respective holes in the I/O shield at the back of the chassis.
3.
Mounting the motherboard onto the motherboard tray:
Carefully mount the motherboard to the motherboard tray by aligning
the board holes with the raised metal standoffs that are visible on the
bottom of the chassis. Insert screws into all the mounting holes on
your motherboard that line up with the standoffs and tighten until snug
(if you screw them in too tight, you might strip the threads). Metal
screws provide an electrical contact to the motherboard ground to
provide a continuous ground for the system.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static electrical
discharge. When unpacking the board, make sure the person handling it is static
protected.
Содержание SUPERSERVER 6013A-T
Страница 1: ...SUPER SUPERSERVER 6013A T USER S MANUAL Revision 1 1b...
Страница 5: ...v Preface Notes...
Страница 10: ...x Notes SUPERSERVER 6013A T User s Manual...
Страница 18: ...1 8 SUPERSERVER 6013A T User s Manual Notes...
Страница 26: ...2 8 SUPERSERVER 6013A T User s Manual Figure 2 4 Installing the Server into a Telco Rack...
Страница 30: ...2 12 SUPERSERVER 6013A T User s Manual Notes...
Страница 34: ...3 4 SUPERSERVER 6013A T User s Manual Notes...
Страница 46: ...5 8 SUPERSERVER 6013A T User s Manual Figure 5 4b Heatsink Installation...
Страница 68: ...6 8 SUPERSERVER 6013A T User s Manual Notes...
Страница 92: ...7 24 SUPERSERVER 6013A T User s Manual Notes...
Страница 94: ...A 2 SUPERSERVER 6013A T User s Manual Notes...
Страница 102: ...B 8 SUPERSERVER 6013A T User s Manual Notes...
Страница 124: ...C 22 SUPERSERVER 6013A T User s Manual Notes...